BLOWER DATA
G61MPV−60C−111 BLOWER PERFORMANCE (less filter)
Side Return Air with Optional RAB Return Air Base
0 through 1.00 in. w.g. External Static Pressure Range
ADJUST"
ADJUST"
Switch
S
tc
P
Positions
iti
+
1
NORM
ADJUST"
Switch
Switch
Positions
+
1
NORM
1
Factory default jumper setting.
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 458 cfm.
G61MPV−60C−111 BLOWER MOTOR WATTS
Jumper Speed
J
S
d
Positions
Positions
0
0.1
+" (Plus) SETTING ( Adjust" Jumper at +" Setting)
HEAT"
Tap 1 165
190
Speed
S
d
Tap 2 210
245
Tap 3 385
415
Tap 4 490
525
COOL"
Tap 1 115
130
S
Speed
d
Tap 2 145
160
Tap 3 180
210
Tap 4 265
295
NORM" (Normal) SETTING ( Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1 140
160
Speed
Speed
Tap 2 175
205
Tap 3 295
320
Tap 4 375
405
COOL"
Tap 1 85
105
Speed
Speed
Tap 2 105
125
Tap 3 135
160
Tap 4 180
210
−" (Minus) SETTING ( Adjust" Jumper at −" Setting)
HEAT"
Tap 1 105
125
Speed
Speed
Tap 2 135
160
Tap 3 210
230
Tap 4 265
295
COOL"
Tap 1 70
85
Speed
Speed
Tap 2 85
100
Tap 3 110
130
Tap 4 145
170
G61MPV / Page 30
Second Stage HEAT" Speed − cfm
1
1
2
1490
1695
1345
1530
1210
1380
First Stage HEAT" Speed − cfm
1
1
2
1365
1555
1235
1410
1115
1270
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
0.2
0.3
0.4
0.5
0.6
225
255
290
320
355
285
330
370
410
450
445
475
505
535
570
565
600
640
680
720
155
180
205
225
250
185
210
230
255
280
240
270
300
330
355
325
360
390
420
450
185
205
230
255
285
235
265
295
330
360
350
380
405
430
455
445
480
515
545
580
130
150
175
190
210
150
175
200
220
240
185
210
235
260
280
240
270
300
330
355
150
170
195
220
240
190
220
250
280
310
255
280
305
335
365
325
355
390
425
465
105
120
140
160
180
120
140
160
185
205
150
175
195
215
235
195
220
245
270
295
Speed Switch Positions
Second Stage COOL" Speed − cfm
3
4
1
1875
2080
1565
1700
1890
1410
1530
1700
1230
3
4
1
1730
1925
1090
1575
1750
995
1410
1565
875
0.7
0.8
0
0.1
385
410
210
245
490
525
270
310
600
625
490
520
760
790
620
660
270
290
310
335
305
330
360
390
380
405
530
570
480
510
715
750
310
340
155
185
395
435
200
235
485
505
360
390
610
640
460
495
225
250
200
230
265
285
270
300
305
330
425
455
385
415
545
580
265
285
135
155
340
365
170
195
395
420
275
300
500
530
350
380
205
220
150
170
225
245
195
220
255
280
300
330
320
345
395
425
2
3
1655
1890
1515
1730
1325
1545
First Stage COOL" Speed − cfm
2
3
1155
1335
1060
1190
935
1070
Second Stage
0.2
0.3
0.4
0.5
0.6
280
320
355
385
410
360
405
455
490
525
560
595
630
660
690
705
750
795
835
870
365
390
415
445
470
425
460
495
525
550
615
655
700
735
775
795
835
875
900
930
215
250
280
310
340
275
320
360
395
435
425
460
490
520
550
540
580
620
660
700
260
295
325
355
385
330
365
395
425
455
490
525
560
590
620
615
651
690
730
770
175
200
225
250
275
226
255
285
320
350
325
350
375
400
430
410
440
475
510
545
195
220
250
275
300
245
270
300
325
355
360
395
430
460
495
455
490
525
550
580
1
4
2060
1900
1695
1
4
1505
1335
1200
0.7
0.8
440
470
560
600
720
745
910
945
500
525
580
605
810
845
960
960
365
395
470
505
585
610
740
770
410
440
485
515
650
685
810
835
300
325
385
420
455
485
580
610
325
350
380
410
530
560
605
635

Advertisement

loading