DIMENSIONS − INCHES (MM) UP−FLOW POSITION SHOWN
1
NOTE − 60C and 60D size units that require air volumes over
1800 cfm (850 L/s) must have one of the following:
a. Single side return air with transition, to accommodate
20 x 25 x 1 in. (508 x 635 x 25 mm) air filter. Required to
maintain proper air velocity.
b. Single side return air with optional RAB Return Air Base
c. Bottom return air.
d. Return air from both sides.
e. Bottom and one side return air.
See Blower Performance Tables for additional information.
2
Optional External Side Return Air Filter Kit (Up−Flow Only) is not
for use with the optional RAB Return Air Base.
A
B
AIR FLOW
C
3/4 (19)
1
Bottom Return
Air Opening
FRONT VIEW
Model No
Model No.
G61MPV−36B−045
G61MPV−36B−070
G61MPV−36B−071
G61MPV−36C−090
G61MPV−60C−090
G61MPV−60C−091
G61MPV−60C−110
G61MPV−60C−111
G61MPV−60D−135
G61MPV / Page 10
9/16 (14)
11−5/8 (295)
Right
9−3/4 (248)
2
OPTIONAL
Left
EXTERNAL
SIDE RETURN
AIR FILTER KIT
(Either Side)
4−7/8 (124) Right
40
(1016)
14−3/4
(375)
16
(406)
5/8 (16)
3/4 (19)
A
in.
mm
17−1/2
446
21
533
24−1/2
622
2
OPTIONAL
EXTERNAL
SIDE RETURN
AIR FILTER KIT
(Either Side)
5−1/2
6−1/2
(140)
(165)
6−1/2
3−1/8
(165)
(79)
4−1/8
6−3/4
(103)
(171)
2−1/4 (57) Left
2−1/2
(64)
4
(102)
18-3/4 (476)
RETURN CUTOUT
4−1/4
(108)
B
in.
mm
16−3/8
416
19−7/8
454
23−3/8
546
SUPPLY AIR
OPENING
23-3/4 (603)
25 (635)
TOP VIEW
28−1/2
(724)
19−7/16
(494)
COMBUSTION AIR INTAKE
(Either Side)
EXHAUST AIR OUTLET
(Either Side)
GAS PIPING INLET
(Either Side)
CONDENSATE
TRAP CONNECTION
(Either Side)
ELECTRICAL INLET
(Either Side)
23
(584)
1
14
OPTIONAL
(356)
(Either Side)
Up−Flow Only
1−15/16 (49)
23−1/2
(597)
1
Bottom Return
Air Opening
SIDE VIEW
C
in.
16
19−1/2
23
9/16
(14)
mm
406
495
584

Advertisement