Sub-assembly B: Holder-Switch Circuit Board Assembly

1. Attach the switch circuit board to the holder-switch circuit board so that the board comes
2. Position the sensor plate by sliding it along the grooves of the holder-switch circuit board and
3. Pass the connector and cable through hole
4. Place the spring-cover on round holder
5. Mount the holder-switch circuit board on the case-upper assembly by aligning tabs
6. Paste the switch panel along the positioning adjustment line of the holder-switch circuit
Rev. A
under tabs
, and secure the board with the screw.
a
by passing the cables below the plate. Pay attention not to close the sensor with the wires.2
slot
and pushing the holder down.
e
board.