Lopi Spirit DV EF Manual page 32

Direct vent freestanding stove
Table of Contents

Advertisement

30
4
Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice
Lift the pilot hood
a
off the pilot
assembly.
5
Install the logs and embers.
6
Close door.
7
Remove the regulator from the front of the gas control valve. Replace with the propane regulator,
using the new gasket and screws included with the regulator. NOTE: Leak test this area after
the heater is installed, gas is connected, and the main burner is lit.
Remove and discard the three screws using a
slotted screwdriver of Torx T-20.
Travis Industries
Optional Equipment
Use a hex wrench to
b
unscrew the orifice.
5/32" Hex
a
b
Remove and discard the
regulator, diaphram, spring
and center post.
Slotted
Screwdriver
(or T-20 Torx)
Remove the orifice and replace with the LP orifice. Screw the
c
orifice all the way in and replace the pilot hood.
NOTE: when re-attaching,
this pin lines up with the
notch in the pilot hood.
Install the LP regulator. Use the screws
included with the LP regulator. Tighten to
approximately 25 Lbs. torque.
Place the LP label on top of
the control cover near the gas
control valve.
4041220
Orifice Identification:
LP (Propane) Orifice
35
35
NG (Natural Gas) Orifice
62
c
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
Slotted
Screwdriver
(or T-20 Torx)
d
1 0 0 - 0 1 1 5 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents