Safety Label - Lopi Spirit DV EF Manual

Direct vent freestanding stove
Table of Contents

Advertisement

26
The listing label is shown below for your records. It can be found inside the left side panel.
Report No. 028-S-09b-5
Certified by OMNI-Test Laboratories, Inc. to the combustion performance and construction requirements of ANSI Z21.44, applicable sections of ANSI Z21.11.1, UL 307b and the
surface temperature requirements of UL/ANSI 1482.
Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1-1992 and NFPA 54(88). Installation in Manufactured or Mobile Homes must
conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280. This model is designed to operate on natural gas, or
propane (LP). This appliance uses a millivolt-type control system consisting of a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a
piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT POWER TO OPERATE. All exhaust gases must be vented outside the structure of
the living-area. Combustion air is drawn from outside the living-area structure. This appliance may be installed in Manufactured Housing only after the home is
site located.
This appliance is equipped for installation in USA 0-2000 ft. For altitudes above 2000 ft., the vent configuration, orifice, or a combination of both may need to be
changed. See the owner's manual for information on making these changes.
WARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the owner's and installation
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the
burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
This room heater is a Direct-Vent Gas-Fired appliance. DO NOT burn wood or other material in this heater.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
Operation of this appliance when not connected to a properly installed nad maintained venting system can result in carbon monoxide (CO) poisoning and
possible death.
CAUTION:
All safety screen or guard components removed for servicing, must be replaced prior to operating the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.
Only use direct vent systems listed in owner's manual to vent this appliance to the exterior.
Minimum Clearances to
Combustibles
Unit to Sidewall . . . . . . . . . . . 10"
Unit to Backwall . . . . . . . . . . 4"
Unit to Cornerwall . . . . . . . . 4"
Front of Unit . . . . . . . . . . . . . 36"
Alcove Min. Height . . . . . . . . 58"
Alcove Max Depth . . . . . . . . 45"
Alcove Min Width . . . . . . . . . 44"
Manufacture
Date:
Travis Industries

Safety Label

Input Rate on "HI" (BTU/Hr) ........... 36,500 38,500
Input Rate on "LO" (BTU/Hr) .......... 21,000 28,700
Main Burner Orifice (DMS)..............
THIS ROOM HEATER IS EQUIPPED AT THE FACTORY FOR USE WITH NATURAL GAS.
If conversion to propane (LP) fuel is desired the optional factory conversion kit #98900746 must be used.
Blower Electrical Rating: 115 V., 1.5 Amps, 60 Hz FAN TYPE VENTED CIRCULATOR
2001
Jan.
Apr.
Jul.
2002
Feb.
May
Aug.
2003
Mar.
Jun.
Sep.
S p i r i t D V
Listed Gas-Fired
Direct Vent Wall Furnace
L.P.
N.G.
Minimum Inlet Pressure (inches W.C.) ..............
Maximum Inlet Pressure (inches W.C.) .............
#50
#32
Manifold Pressure on "HI" (inches W.C.)..........
Oct.
Nov.
Dec.
10850 117th Pl. N.E. Kirkland, WA 98033
4041220
L.P. N.G.
11"
5.5"
13"
7"
10"
3.5"
0274
1 0 0 - 0 1 1 5 3