Characteristic Of Temperature Sensor - Electrolux EXP09CN1W Service Manual

Portable air conditioner
Table of Contents

Advertisement

and then gradually move back to infinity.
4. Reverse the leads of the probe and momentarily touch the capacitor terminals. The deflection
of the pointer should be two times that of the first check if the capacitor is good.
5. Repeat steps 3 and 4 to check fan motor capacitor.
NOTE: A shorted capacitor will indicate a low resistance and the pointer will move to the "0" end
of the scale and remain there as long as the probes are connected.
An open capacitor will show no movement of the pointer when placed across the terminals of the capacitor

9 Characteristic of temperature sensor

Temp.℃
-10
-9
-8
-7
-6
-5
-4
-3
-2
-1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Resistance
Temp.℃
62.2756
17
58.7079
18
56.3694
19
52.2438
20
49.3161
21
46.5725
22
44
23
41.5878
24
39.8239
25
37.1988
26
35.2024
27
33.3269
28
31.5635
29
29.9058
30
28.3459
31
26.8778
32
25.4954
33
24.1932
34
22.5662
35
21.8094
36
20.7184
37
19.6891
38
18.7177
39
17.8005
40
16.9341
41
16.1156
42
15.3418
43
Resistance
Temp.℃
14.6181
44
13.918
45
13.2631
46
12.6431
47
12.0561
48
11.5
49
10.9731
50
10.4736
51
10
52
9.5507
53
9.1245
54
8.7198
55
8.3357
56
7.9708
57
7.6241
58
7.2946
59
6.9814
60
6.6835
61
6.4002
62
6.1306
63
5.8736
64
5.6296
65
5.3969
66
5.1752
67
4.9639
68
4.7625
69
4.5705
70
34
Resistance
4.3874
4.2126
4.0459
3.8867
3.7348
3.5896
3.451
3.3185
3.1918
3.0707
2.959
2.8442
2.7382
2.6368
2.5397
2.4468
2.3577
2.2725
2.1907
2.1124
2.0373
1.9653
1.8963
1.83
1.7665
1.7055
1.6469

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Exp09hn1wExp12hl1w

Table of Contents