JVC DOME TYPE CAMERA TK-C676 Instructions Manual page 22

Dome type camera
Hide thumbs Also See for DOME TYPE CAMERA TK-C676:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Setting Up the Camera Using an RM-P2580
CAMERA TITLE/ALARM Screen (Continued)
Item
ALARM INPUT ..
(Continued)
POLARITY
Sets the polarity of the alarm signal inputs.
MAKE
BREAK : Alarm signals are transmitted when contact is broken.
MEMO
When an item for the B&W is set to the ALARM 1 to 4, it is set to the MAKE mode even if
"BREAK" is displayed.
DURATION
Sets the length of an alarm operation once an alarm signal has been transmitted.
(Unit:second)
Setting values : 5s, 6s, 7s, 8s, 9s, 10s, 15s, 20s, 30s or 60s
CAUTION
This item is invalid with the system using the RM-P2580. When using the RM-P2580, use
item "ALARM TIME" instead.
PRIORITY
Sets whether or not manual operation is accepted in case an alarm input is recog-
nized during manual operation of the camera.
ALARM
MANUAL : Manual operation is accepted even when there is an alarm input.
CAUTION
This item is invalid with a system using the RM-P2580. With this system, the ALARM input
is permanently given the priority.
ALARM OUTPUT ..
Sets the configuration of the alarm output terminals on the Ceiling Mount.
ALARM OUT1
Sets the configuration of the Alarm output 1 terminal.
OFF
ALARM
B&W
PRESET : Alarm signal is output when a camera moves to a preset position.
AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This
ALARM OUT2
Sets the configuration of the Alarm output 2 terminal.
OFF
ALARM
B&W
PRESET : Alarm signal is output when a camera moves to a preset position.
AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This
ALARM OUT3
Sets the configuration of the Alarm output 3 terminal.
OFF
ALARM
B&W
PRESET : Alarm signal is output when a camera moves to a preset position.
AUX1 to 3 : Alarm signal is output when a corresponding AUX signal is input. (This
E-22
: Alarm signals are transmitted when point of contact is made.
: Manual operation is not accepted when there is an alarm input.
(Priority on alarm)
(Priority on manual)
: Does not output an alarm signal.
: Alarm signal is output upon input of motion detection or an alarm signal.
: Alarm signal is output when the camera enters the B&W mode.
is variable depending on the remote control unit in use.)
MEMO
Since the ALARM OUT 1 terminal employs a mechanical relay, its operating sound may
seem noisy in a quiet environment. In this case, use the ALARM OUT 2 or 3 terminal
instead.
Sine the ALARM OUT 1 terminal employs a mechanical relay, the service life of the relay
may be shortened if signals causing an alarm (motion detect signal, etc.) are applied fre-
quently. The service life of a relay is 200,000 times of operation. The relay is a consumable
part and a replacement is chargeable even before the termination of the warranty period.
: Does not output an alarm signal.
: Alarm signal is output upon input of motion detection or an alarm signal.
: Alarm signal is output when the camera enters the B&W mode.
is variable depending on the remote control unit in use.)
: Does not output an alarm signal.
: Alarm signal is output upon input of motion detection or an alarm signal.
: Alarm signal is output when the camera enters the B&W mode.
is variable depending on the remote control unit in use.)
Function & Setting
Initial Value
MAKE
5s
ALARM
ALARM
ALARM
ALARM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tk-c676e(a)

Table of Contents