SYSTEM CONFIGURATION AND SETUP OPTIONS:

Setup options for how the thermostat will function, along with choosing your
particular system type, are performed using a menu on the display screen.
TO ACCESS THE SETUP MENU: Move the System Mode switch into the OFF
position, and then hold down the SET button for approximately 5 seconds until
the screen changes. The menu will always start with item #01, and is advanced
to each following item by a single press of the NEXT button. The options for each
item are changed using the UP or DOWN buttons.
ITEM #01 (TEMPERATURE SCALE):
[1] (default) Shows all temperature values in Fahrenheit.
[2] Shows all temperature values in Celsius.
ITEM #02 (PROGRAMMING STYLE):
[1] (default) 5/2-Day Programming. This style uses a weekday program routine
for Monday, Tuesday, Wednesday, Thursday, Friday, and a separate weekend
program routine for Saturday and Sunday.
[2] 7-Day Programming. This style uses a separate program routine for each of
the 7 days in the week. [3] Manual Non-Programmable. In this setting, there are
no program routines for the thermostat to follow and the temperature control will
be set only by the UP and DOWN buttons on the front panel.
ITEM #03 (PERIOD QUANTITY):
[1] (default) 4-Periods. Thermostat uses four periods per day (called MORN, DAY,
EVE, and NITE).
[2] 2-Periods. The thermostat uses only two periods per day (called DAY and
NITE).
ITEM #04 (MAXIMUM HEAT SET TEMP LIMIT):
[1] (default) Limit 90F (32C). The maximum heating set temperature is 90F (32C)
degrees with no heat mode temperature restrictions.
[2] Limit 80F (27C). The maximum heating set temperature is 80F (27C) degrees.
[3] Limit 70F (21C). The maximum heating set temperature is 70F (21C) degrees.
[4] Limit 60F (16C). The maximum heating set temperature is 60F (16C) degrees.
ITEM #05 (MINIMUM COOL SET TEMP LIMIT):
[1] (default) Limit 45F (7C). The minimum cooling set temperature is 45F (7C)
degrees with no cool mode temperature restrictions.
[2] Limit 55F (13C). The maximum cooling set temperature is 55F (13C) degrees.
[3] Limit 65F (18C). The maximum cooling set temperature is 65F (18C) degrees.
[4] Limit 75F (24C). The maximum cooling set temperature is 75F (24C) degrees.