PSPHA732
PSPHA732
1. COMPATIBILITY
Your PSPHA732 is compatible with Heat Pumps
Up to 3 Stages of Heat and 2 Stages of Cooling.
This includes Auxiliary and Emergency Heat. It
cannot be used with 120 volt heating systems or
3 wire zone valves. Ask your dealer for other
LUXPRO thermostats to control those systems.
2. FEATURES
• Heating and Cooling
• Electronic
• Programmable
• 7 Day Programming (Each day can be different)
• Auxiliary and Emergency Heat Indicators
• Programming Copy Button
• Large Display
• Electro-luminescent Display Backlight
• Clean Cycle™ IAQ Independently Programmable
Fan
• ENERGY STAR
®
Compliant
• 4 Periods Per Day
• Temporary Override 1-4hr (CAT24 Compliant)
• Hold
• Optional Smart Recovery
• Easy Programming with LUX Speed Dial
®
UP
DOWN
LIGHT
IAQ
INDEPENDENTLY
PROGRAMMABLE
FAN
MODE SWITCH
• Programmable Filter Monitor and Indicator
• Energy Usage Monitor
• Battery Free Nonvolatile Memory For All
Programs And Settings
• Battery or System Powered with Battery Backup
• Batteries Included (2 AA)
• Auto-Changeover
• Programmable Auto-Changeover Dead band
(1˚ to 6˚ F) (1˚ to 3˚ C)
• Keyboard Lockout
• Temperature Offset (User Calibration)
• On Screen Low Battery Indicator
• F/C Temperature Display
• 12/24 Hour Clock
• 2 or 5 Minute Short Cycle Protection
• 1 Minute Optional Residual Fan
• Multi-Stage Adjustable Temperature Differential
/ Cycle Rate
• Terminals: E, C, Y1, R, Y2, W, B, O, G
3. ELECTRICAL RATINGS
• 30V maximum (24VAC nominal)
• 1.5A maximum per terminal
• 2.0A terminal sum
2
CAUTION:
Your thermostat is protected against
normal static electric discharges. To
minimize the risk of damaging the unit in
extremely dry weather, touch a grounded
metal object before touching your
thermostat.
4. INSTALLATION
4.1 TOOLS REQUIRED
• #1 Phillips screwdriver (small)
• Drill with 3/16-in. (4.8mm) bit
• Wire stripper/cutter
4.2 LOCATION
• On replacement installations, mount the new
thermostat in place of the old one, unless the
conditions listed below suggest otherwise. On
new installations, follow the guidelines listed
below.
• Locate the thermostat on an inside wall, about 5
ft. (1.5m) above the floor, in a room that is used
often.
• Do not locate where air circulation is poor, such
as in a corner or an alcove; or behind an open
door.
• Do not install it where there are unusual heating
conditions, such as: in direct sunlight; near a
lamp, television, radiator, register, or fireplace;
near hot water pipes in a wall; near a stove on
the other side of the wall.
• Do not locate in unusual cooling conditions,
such as: on a wall separating an unheated room;
or in a draft from a stairwell, door, or window.
• Do not locate in a damp area. This can lead to
corrosion that will shorten thermostat life.
• Do not install the unit until all construction work
and painting has been completed.
WARNING:
• Read instructions carefully before
removing any wiring from an existing
thermostat.
• Label wires before they are removed.
• When removing wires from their
terminals, ignore the color of the wires
since they may not comply with any
standard.
4.3 REMOVAL OF OLD UNIT
1. Switch electricity to the furnace and air
conditioner OFF; then proceed with the following
steps.
2. Remove cover from old thermostat. Most are
snap-on types and simply pull off. Some have
locking screws on the side. These must be
loosened.
3. Note the letters printed near the terminals.
Attach labels (enclosed) to each wire to
identification. Label and remove wires one at a
time. Make sure the wires do not fall back inside
the wall.
4. Loosen all screws on the old thermostat and
remove it from the wall.
4.4 MOUNTING
5. Strip insulation 3/8 in. (9.5mm) from wire
ends and clean off any corrosion.
6. Fill wall opening with non-combustible
insulation to prevent drafts from affecting the
thermostat.
7. With each thumb on a release tab at the
bottom of the body, and fingers over the top of
the unit, release the unit from its base plate by
squeezing the tabs into the body.
8. Separate the unit from its base plate by pulling
the body outward at its bottom.
3

Advertisement

loading

Summary of Contents for Lux Products PSPHA732

  • Page 1 • On replacement installations, mount the new loosened. • Energy Usage Monitor Your PSPHA732 is compatible with Heat Pumps thermostat in place of the old one, unless the 3. Note the letters printed near the terminals. • Battery Free Nonvolatile Memory For All Up to 3 Stages of Heat and 2 Stages of Cooling.
  • Page 2 CAUTION: Y2 Active while calling for a 2nd stage of NOTE: If you have an electric system and 5.4 EMERGENCY (EMER) the blower does not operate after heating/cooling. • Be careful not to drop the unit or disturb • Use EMERGENCY position on slide switch to installation, verify that the electric/gas electronic parts.
  • Page 3 • If a second stage of heat is called for, the 5.11 OVERRIDE 5.12.3 CLEAN CYCLE™ PERIOD HEAT MODE COOL MODE flashing rate of HEAT increases During RUN, set temperatures may be • LUX’s Clean Cycle™ allows you to program a Morning 6:00 AM 70 F (21...
  • Page 4 to accept the displayed start time and advance to 6.3 CLEAN CYCLE™ (IAQ FAN 0 to 60 minutes in increments of 3 minutes. Set 7.2 FILTER MONITOR the HEAT SET TEMPERATURE, it will flash to PROGRAMMING) 0 MIN/HR to allow AUTO control for particular •...
  • Page 5 • Use UP/DOWN keys to adjust the filter limit in • Use the UP/DOWN keys to adjust the offset 3 to 6 times per hour. A smaller swing number To change this value: 10-hour increments to the recommended value. value. increases the number of cycles, so room •...
  • Page 6 board. For reference, there are a table of settings comfort period must be higher than the setback 9.1 BATTERY INSTALLATION not allow limitations on how long an implied and jumper positions printed there as well. They period. warranty lasts, so the above limitation may not 1.
  • Page 7 12. WIRING DIAGRAMS 13. CROSS REFERENCE CHART FOR MULTI-STAGE HEAT PUMPS HEAT PUMP SYSTEM NEW THERMOSTAT AND TAPE OFF WITH COMMON TERMINAL CORRESPONDING TERMINALS NOT USED AMANA RC-RH AMANA PHD-2,-3,-4,or -5 ARCO / Friedrich ARCO / Snyder General BARD BARD, HP, WH, MHP, HPQ BDP / BRYANT (W2) BDP 34427DP97...
  • Page 8 14. SOFTWARE RESET TABLE PSPHA732 SERIES Before hitting the software reset button, record your thermostat’s programs and settings in the table provided below. SMART TEMP ® ELECTRONIC THERMOSTAT HEAT COOL PERIOD TIME TEMP. TIME TEMP. INSTALLATION AND OPERATING INSTRUCTIONS MORN...