4. SYNC OSD Display
If EXIT icon is selected, press SELECT key to close OSD menu and then display sync information for 2
sec. This sync information will not be close until release SELECT key (Fig. 11).
5. Factory mode
Press SELECT key + UP key and power on, system enter factory mode.
OSD will display "FA" to indicate in factory mode (Fig. 12 – 13).
Operation of factory mode is same as normal mode except below 2 condition:
a. adjustment value is saved to user and factory area.
b. R, G, B value are saved to current color temperature.
6. OSD Move Mode
Press DOWN key and power on, system enter OSD move mode, user can move OSD display position
in this mode.
Press SELECT key then OSD display following figure (Fig. 14) and only 3 icons OSD H-position / OSD
V-position / ESC can be selected.
Fig. 12
Fig. 11
Fig. 14
9
Fig. 13