Air Top Evo 3900/5500
2
General description
The Air Top Evo 3900 and Air Top Evo 5500 air heaters
are based on the evaporator principle and essentially
consist of the following
–
The drive unit with a combustion and hot air blower
–
The heat exchanger
–
The burner insert with combustion pipe
–
The control unit
To control and monitor it, the heater has
–
a control unit with temperature sensor
–
a glow plug / flame monitor
–
an overheating sensor
inside it.
Air Top Evo 3900/5500 air heater
2 General description
The fuel supply is provided from an external source using
a metering pump.
If a fault occurs, an error code will be output in the display
of the combination or standard timer. If the heater has a
control element, the ON control light will flash.In addition
the heater can be checked using a personal computer
(see PC heater diagnostic operating manual).
The heater may be controlled using an external
temperature sensor instead of the internal temperature
sensor.
Air Top Evo 3900/5500 air heater without casing
201