Private Line Format
The Private Line format will only transmit zone alarms for which reporting codes are programmed in Section [11];
[F], [A] and [P] Key alarms will not be reported by this format. Do not program any reporting codes other
than the Alarm Reporting Codes for Zones 1 through 4 and the Tamper Zone. When a zone goes into alarm,
the system will dial the telephone number programmed in Section [08]. The system will make up to eight
attempts to communicate to the First Phone Number. After eight unsuccessful communication attempts, the
system will dial the Second Phone Number programmed in Section [09].
When the call is answered, a double "beep" will sound on the line to indicate to the listener that a security
system is placing a call. Press 3, 6, 9 or # on a touch-tone telephone to have the system transmit the zone
or zones that are in alarm. The system will indicate which zone is in alarm by sounding a number of tones.
One tone will sound for Zone 1, two tones will sound for Zone 2, and so on. Note that 5 tones will sound for
a Tamper Zone alarm.
When the system has sounded the tones to indicate which zone is in alarm, it will wait for approximately 5
seconds for the listener to key in a closing handshake. Pressing 3, 6, 9 or # will send a closing handshake
to the system. When the system receives the handshake, it will either hang up or will sound additional
tones to indicate the next zone that is in alarm.
40BPS Non-Extended 4/2 with Parity Format
This communication format requires a 4-digit Account Code to be programmed in Section [10] and 2-digit
reporting codes to be programmed in Sections [11], [12] and [13]. When an event is reported, the 4-digit
Account Code, the appropriate 2-digit Event Code and a 1-digit parity character are transmitted. Since this
format uses parity, only one round needs to be transmitted per event. Ensure that the handshake (Section [06]
Light 2) is programmed to match the receiver to which the system will communicate.
[07]

3rd System Option Code

Refer to Section [05] for programming information.
LIGHT
[1]
ON =
Swedish Pulse Dialing
• OFF =
Standard Pulse Dialing
[2] • OFF =
For Future Use
For Future Use
[3] • OFF =
[4] • OFF =
For Future Use
• Factory default settings
Standard Pulse Dialing: 1 is transmitted as one pulse, 2 is transmitted as two pulses, and so on; 0 is
transmitted as ten pulses. Swedish Pulse Dialing: 1 is transmitted as two pulses, 2 is transmitted as three
pulses, and so on; 0 is transmitted as one pulse. Setting the pulse dialing option will depend on the pulse
dialing method used by the telephone company.