Wiring; Earthing Instructions; Servicing Of Earthing Products - Amana Menumaster DECS11MA Service

1100 w - 2005 international countertop commercial microwave ovens
Table of Contents

Advertisement

Important Safety Information
!
WARNING
Precautions to be observed before and during
servicing to avoid possible exposure to excessive
microwave energy, or electrical shock disconnect
power to oven.
(A) Do not operate or allow oven to be operated with
door open.
(B) Make the following safety checks on all ovens to
be serviced before activating the magnetron or
other microwave source, and make repairs as
necessary:
• Interlock operation
• Proper door closing
• Seal and sealing surfaces (arcing, wear, and
other damage)
• Damage to or loosening of hinges and latches
• Evidence of dropping or abuse
(C) Before turning on microwave power for any service
test or inspection within the microwave generating
compartments, check the magnetron, waveguide or
transmission line, and cavity for proper alignment,
integrity, and connections.
(D) Any defective or misadjusted components in the
interlock, monitor, door seal, and microwave
generation and transmission systems shall be
repaired, replaced or adjusted by procedures
described in this manual before oven is released to
the consumer.
(E) Check microwave leakage to verify compliance with
the federal performance standard should be
performed on each oven prior to release to the
consumer.

Wiring

Good service practice is to never route wiring over
terminals and/or sharp edges. This applies to any wiring
without regard to the circuit voltage. Wire insulation
material and thickness is designed and regulated for
electrical spacing purpose only, but cannot always be
relied upon because of possible cuts and/or abrasions,
which can occur during servicing.
8
To avoid risk of electrical shock, personal injury or
death, make sure these earthing instructions are
followed.

Earthing Instructions

Do not remove earthing prong when installing earthed
appliance in a home or business that does not have
three wire earthing receptacle, under no condition is
earthing prong to be cut off or removed. It is the
personal responsibility of the consumer to contact a
qualified electrician and have properly earthed three
prong wall receptacle installed in accordance with
appropriate electrical codes
Should a two prong adapter plug be required temporarily,
it is the personal responsibility of the consumer to have it
replaced with properly earthed three prong receptacle or
the two prong adapter properly earthed by a qualified
electrician in accordance with appropriate electrical
codes.
Servicing of Earthed Products
The standard accepted color coding for earthing wires is
GREEN or GREEN WITH YELLOW STRIPE. These
earth leads are NOT to be used as current carrying
conductors. It is extremely important that the technician
replace any and all earths prior to completion of the
service call. Under no condition should earth wire be left
off causing a potential hazard to technicians and
consumer.
16025963
!
WARNING
!
WARNING
©2005 Maytag Services