Control Panel; Interlock Switches - Amana Menumaster DECS11MA Service

1100 w - 2005 international countertop commercial microwave ovens
Table of Contents

Advertisement

Disassembly Procedures
!
WARNING
!
CAUTION
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembly, or
adjusted for any reason.
Control Panel Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Disconnect and label wires from controller/timer.
3. Open oven door.
4. Remove screw securing top of control panel to cavity.
Lift control panel up and out to release tabs.
5. Replace component and reverse procedure to
reassemble.
©2005 Maytag Services
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.

Interlock Switches

Primary switch is operated by bottom latch arm.
Interlock Switch Removal
1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Remove control panel, (see "Control Panel" section).
3. Test interlock switches before removing, (see testing
procedures).
4. Disconnect and label wire connections.
5. Remove mounting screws securing interlock switch to
unit chassis.
6. Replace component and reverse procedure to
reassemble.
Monitor
Switch
Primary
Switch
Secondary
Switch
NOTE: After repairing the door or the interlock system, it
is necessary to check the switch continuity
before operating the oven.
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
operation, all switches and controller must be
replaced.
16025963
NC
COM
COM
NO
COM
Tab
!
CAUTION
Tab
NO
27