Amana Menumaster DECS11MA Service page 16

1100 w - 2005 international countertop commercial microwave ovens
Table of Contents

Advertisement

Troubleshooting Procedures (Electronic Models)
Trouble 5:
No microwave oscillation even when oven light and fan motor operate.
No microwave
oscillation.
Operates at
full power
when
programmed
for lower
power.
16
Disconnect wire
leads from relay
RY2 and verify
3
continuity of the
relay.
Check high
voltage
transformer.
Check high
voltage capacitor.
Check high voltage
diode.
Check magnetron.
Disconnect wire
leads from relay
3
RY2 and verify
continuity of the
relay.
No
Failed
Continuity
controller.
Continuity
Abnormal
Failed high
voltage
transformer.
Normal
Failed high
Abnormal
voltage
capacitor.
Normal
Failed high
Abnormal
voltage
diode.
Normal
Abnormal
Failed
magnetron.
Failed
Abnormal
controller.
16025963
Replace
controller.
Replace high
voltage
transformer.
Replace high
voltage capacitor.
Replace high
voltage diode.
Replace
magnetron.
Replace
controller.
©2005 Maytag Services

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents