Disassembly Procedures
!
WARNING

Transformer

1. Disconnect power to oven and remove outer case,
(see "Outer Case" procedure).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Disconnect and label wire leads from transformer.
4. Remove screws securing transformer and remove.
5. Replace transformer and reverse procedure to
reassemble.

Fuse / Fuse Block / Filter Assembly

1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Disconnect and label wires.
3. Remove fuse to gain access to screws securing
assembly.
4. Carefully lift tab to release assembly from locating
pin.
5. Replace component(s) and reverse procedure to
reassemble.
!
CAUTION
Before replacing a blown monitor fuse, test the primary
interlock switch, secondary interlock switch, monitor
switch, and power relay contacts for proper operation.
If the monitor fuse is blown by a failed switch
operation, all switches and controller must be
replaced.
©2005 Maytag Services
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.

Magnetron

Magnetron is located on the side of the cavity.
1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Discharge high voltage capacitor, (see "High Voltage
Capacitor" section).
3. Remove terminal plug from filament terminals.
4. Remove screws securing magnetron cutout bracket to
magnetron.
5. Remove screws securing magnetron to the wave
guide.
Chassis
6. Replace magnetron and reverse procedure to
reassemble.
NOTE: When replacing magnetron, make sure gasket is
in correct position and in good condition.
During replacement of magnetron, be certain the R.F.
anode gasket is in place around the anode stud.
A microwave leakage test must be performed anytime
a magnetron assembly is removed, replaced,
disassembled, or adjusted for any reason.
16025963
Antenna
Filament
!
CAUTION
!
WARNING
Gasket
29

Hide quick links:

Advertisement

Table of Contents
loading