Volvo Penta IPS Operator's Manual page 31

Marine engine
Hide thumbs Also See for IPS:
Table of Contents

Advertisement

P0001218
P0001203
P0001203
P0001015
P0001015
P0001022
P0001022
P0001021
P0001021
7748921 04-2008
No Protection; risk of corrosion, system gives warn-
ing alarm. The display switches between the two
screens.
Seek service for system checks.
If the ACP is set to inactive, the system cannot iden-
tify ACP status and three lines will be shown on the
display.
If this should occur when the system is not set to
inactive, seek service for checks.
ACP will also show the three lines during one minute
after ignition is turned on, thereafter it will show cur-
rent protection level.
Settings
ACP has three function modes; these are set in the
EVC menu under Settings/ACP. Refer to Settnings
menu page 102, section ACP.
Normal means that the system is active and working
in the optimal manner.
Chlorine Free means that the system has switched
over to protection by the zinc anode for 4 h, resulting
in no chlorine gas being given off.
Optional
29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents