MOOULE
3-l: CAM TANK MODULE
1 . Unplug th€ projector and open the rear cover.
2. Remove the 3 transformer mounting $erews
and unplug the transformer- {See Sec 34}
3. Remove the motor belt.
4- Remove the main driving belt by releasing the
tension gear.
5. Retract the claw by turning the inching knob.
6. Open the lamphouse and remove the lamp and
holder asscmbly by unscrewing the knurled
nut-
7. Unscrew the two cam tank mounting screws.
8. Remove the cam tank slowly and carefully.
Care *rould be taken to avoid darnaging the
claw by striking it against the main casting.
9. Re-installation can be done by the reverse
procedure. Care should be taken that the cam
tank worm gear and main drive fiber gear do
not bind. A small amount of gear lash is
required ta prevefit abnormal wear.
10. To check the timing and cla',v adjustments,
refer to Sec. 5-1 and 6-3-
Fis. #24
Frs. #23
iIOTOR IfrODULE
3-2: AMPLIFIER MODULE
1. Remove the flywheel-
2. Unplug the rsar cover speaker cord.
3. Remove the volume, bass and treble knobs.
NOTE: cn magnetic models remov€ the mag/opr
knob.
4. Unplug the MT 9 pin plug.
5. Unplug the sslar cell and magnetic lezd miniature
plug.
6. Rernove the two phillips scfe$rg, one at each end
of the amplifier.
7. The amplifier can now be removed by sliding
out.
8. To re-install, rwerse the procedure above. Be
sure that the indicator on the controls lines up
and all thc connectors are sccurd.
Fis. #25
q
AMPLIFIER ITIOBULE
- x t -