Codablock A / Codablock F

Read the following symbols to enable/disable Codablock A and Codablock F settings:
Codablock A On
Codablock F On
Codablock by ESP
Important: When Codablock F and Code 128 are both enabled, there is some risk of
mistakenly decoding a damaged Codablock F symbol as a Code 128 symbol. Therefore,
whenever possible, Code 128 should be disabled when Codablock F is enabled.
Using Codablock F On will disable Code 128. Using Codablock F Off will re-enable
Code 128.
Sample Codablock F Symbol
HS-2D Handheld Reader User's Manual
Codablock A Off (Default)
Codablock F Off (Default)
Symbologies
5-5