Pump Reassembly/Installing New Seal - STA-RITE MAX-E-PRO Owner's Manual

Max-e-pro p6ra/p6ea/p6e series centrifugal pumps with integral trap
Hide thumbs Also See for MAX-E-PRO:
Table of Contents

Advertisement

periodic cleaning of strainer basket. If shaft seal is worn
or damaged, repair as follows:
Pump Disassembly/Removing Old Seal
Disconnect power to pump motor.
Be sure gate valves on suction and return piping
are closed before starting work.
Release all pressure by opening all vents before
starting work.
1. Drain pump by removing drain plugs on bottom of
pump body and trap body.
2. Be sure there is no pressure in trap body; remove
cover (unscrew by turning handle ring
counterclockwise).
3. Remove clamp holding pump halves together. Motor
and seal plate assembly can now be pulled away
from pump body.
4. Remove five screws and washers holding diffuser to
seal plate. Remove diffuser.
5. Remove motor canopy. Being careful not to touch
capacitor terminals, loosen capacitor clamp and
move capacitor to one side.
6. Hold shaft with 7/16" open-end wrench on motor
shaft flats.
7. Unscrew impeller from shaft (turn counterclockwise
when facing it).
NOTICE: On models with impeller screw: Remove
impeller screw (left hand thread - turn clockwise)
and gasket before removing impeller. Inspect
gasket for damage, cracks, etc. Replace if
damaged.
8. Pull rotating member of seal off of impeller sleeve;
clean sleeve.
9. Remove four screws holding seal plate to motor.
10. Place seal plate face down on flat surface and tap
out ceramic seat.
11. Clean seal cavity in seal plate and clean motor
Figure 5: Press seal into seal plate
shaft.
4301 0103

Pump Reassembly/Installing New Seal

1. Ceramic seat must be clean and free of dirt, grease,
dust, etc. Wet outer edge of rubber cup on ceramic
seat with small amount of liquid detergent; press
ceramic seat into seal plate firmly and squarely with
finger pressure (Figure 5).
2. If ceramic seat will not locate properly, remove it,
place face up on bench and reclean cavity. Ceramic
seat should now locate.
3. If seat still will not locate properly, place a
cardboard washer over the polished face and use a
piece of 3/4" (19mm) standard pipe for pressing
purposes.
NOTICE: Be sure not to scratch or mar polished
surface or seal will leak.
4. Remount seal plate on motor. Tighten bolts to 60-
80 inch-lbs. (69-92 kg/cm) torque.
5. Apply a small amount of liquid detergent to inside
diameter of rotating half of seal.
6. Slide rotating seal member, polished face last, over
impeller sleeve until rubber drive ring hits shoulder.
NOTICE: Be sure not to nick or scratch polished
seal face; seal will leak if face is damaged.
7. Screw impeller onto shaft (clockwise); this will
automatically locate seal in seal plate.
NOTICE: On models with impeller screw: Install
impeller gasket and lock screw (left-hand thread -
turn counterclockwise). Torque lock screw to 50-55
inch-lbs. (57.6-63 kg/cm).
8. Mount diffuser on seal plate; tighten screws to
10-14 inch-lbs. (11.2-16.1 kg/cm) torque.
9. Assemble motor and seal plate to volute; be sure
clamp is properly seated.
NOTICE: Clamp knob can be located in any
position around volute; if it is moved after assembly,
tighten knob while tapping around clamp to assist
sealing. Do not move clamp while pump is full of
water.
Hazardous pressure. Release all
pressure from pump and piping system before
working on pump or attempting to adjust or remove
clamp. Clamp may blow off of pump if adjusted
under pressure.
10. Prime pump according to instructions on Page 9.
11