Technical Data
Climatic conditions in accordance with IEC 60721-3-4
Installation type C, class 4K4H
Extended temperature range
Extended humidity range
Extended air pressure range:
Transport type E, class 2K3
Temperature range

Protective Devices

DC reverse polarity prevention
All-pole DC disconnection unit
DC overvoltage protection
Personal protection (Riso > 1 M Ω )
AC short circuit protection
All-pole AC disconnection unit
Maximum fuse protection
Galvanic isolation

General data

Width x height x depth with Electronic Solar
Switch
Weight
Width x height x depth of packaging
Transport weight
Operating temperature range
Maximum operating altitude above mean sea
level
Noise emission (typical)
Internal consumption in night mode
Topology
Protection rating according to IEC 60529
Cooling concept
Protection class
84
SB20_25_30HF-IEN102911
SMA Solar Technology AG
− 25 °C ... +60 °C
0 % ... 100 %
79.5 kPa ... 106 kPa
− 25 °C ... +70 °C
Short-circuit diode
Electronic Solar Switch,
DC plug system SUNCLIX
Thermally monitored varistors
Insulation monitoring
Current control
Automatic disconnection device
SMA Grid Guard 3
25 A
available
348 mm x 580 mm x 145 mm
17 kg
450 mm x 600 mm x 400 mm
21 kg
− 25 °C ... +60 °C
3,000 m
No data
< 1 W
HF transformer
IP65
OptiCool: temperature-controlled fan
I
Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000hf

Table of Contents