Belling IH6013 Users Manual & Installation Handbook page 11

Belling ih6013 induction hob users guide & installation handbook
Hide thumbs Also See for IH6013:
Table of Contents

Advertisement

USING THE HOB (13 AMP VERSIONS)
13 AMP OPERATION
Your hob has been designed to allow you to connect to a 13Amp fused spur and is
suitable for a variety of installations not possible with conventional electric hobs, such
as direct replacement for a gas hob without the need to install a 32 Amp cooker socket,
thus eliminating the need for an expensive rewire of the kitchen.
How it works
Each time you operate the hob, the total power level of the hob is calculated.
If the total power requested reaches 2.8 kW the energy management system warns
you that the limit is reached. Signalled by a letter "r" in the zone window (Lasts for 3
seconds ) and an audible "Beep". The hob cook zones can be used in any combination
or setting until the 2.8 kW power setting is reached. (See Tables Below)
Any further power increase is not allowed!
To use any new zones requires you to reduce the power of one of the other selected
cook zones.
Set Cook Zone
Left Hand Front
Left Hand Rear
Right Hand Front
Right Hand Rear
"13 Amp Supply" Power Management Check
Set Cook Zone
Left Hand Front
Left Hand Rear
Right Hand Front
Right Hand Rear
Warning! If you can set a power level on the right hand cook zone when the
other zones are set as above. Please switch off and contact customer service for
13 Amp Supply Power Setting Examples
Examples Of Possible Power Setting Combinations
9
9
1
Off
Correct Power Setting Check "13 Amp Supply"
"r" and warning "Beep" when zone is activated
6
1
6
3
5
4
5
P
9
9
1
advice.
6
Off
Off
P
4
9
9
Off

Hide quick links: