13. Remove the Clips holding the Gas Springs to the Actuator Yoke, then
remove the actuator assembly from the machine.
14. Disconnect the two Pivot Links from the deck weldment. Note that
there is a Bushing in the Left-hand Pivot Link and a Flange Bearing in
the Right-hand Pivot Link (as viewed from the operator position).
15. Disconnect the Turnbuckle from the deck weldment.
32 - Form No. 56043161 - Clean Track
L24
®
Clip
Gas
Spring
Left-hand
Pivot Link
Bushing
Right-hand
Flange
Pivot Link
Bearing
Turnbuckle