All-Power APGG4000 Owner's Manual

All-Power APGG4000 Owner's Manual

4000 watt generator
Hide thumbs Also See for APGG4000:

Advertisement

4000W Generator
Topic
i L
m
i
e t
d
W
r a
a r
n
y t
S
a
e f
y t
G
u
d i
e
n i l
e
s
G
e
n
r e
l a
P
e r
c
a
t u
o i
n
s
Compliance
G
e
n
r e
l a
P
r a
s t
L
t s i
n i
g
WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS
IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH
INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL
INJURY, PROPERTY DAMAGE, AND/ OR VOIDING OF YOUR
WARRANTY. ALL-POWER WILL NOT BE LIABLE FOR ANY DAMAGE
BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.
4000W Generator
Page
3
5
6
15
16
17
22
23
29
31
32
3
3
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the APGG4000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for All-Power APGG4000

  • Page 1: Table Of Contents

    IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/ OR VOIDING OF YOUR WARRANTY. ALL-POWER WILL NOT BE LIABLE FOR ANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS. 4000W Generator...
  • Page 2 4000W Generator Owner’s Manual Safety Guidelines - Definitions General Precautions This manual contains important information that you need to know and WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN understand in order to protect YOUR SAFETY and to PREVENT SEVERE INJURY OR DEATH.
  • Page 3 Owner’s Manual 4000W Generator General Precautions (cont’d) General Precautions (cont’d) Electrical Safety (cont’d) Personal Safety (cont’d) • Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect • All connections and conduits from the generator to the load must only be installed by trained and the spark plug wire when not in use.
  • Page 4: Battery

    Owner’s Manual 4000W Generator General Precautions (cont’d) General Precautions (cont’d) Extension Cord Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not If an extension cord (not included) is used, make sure to use only UL approved cords having the attempt to reach around the safety guard for maintenance or any other reason.
  • Page 5: Operation

    CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. ALL-POWER IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER.
  • Page 6: Spark Plug Service

    4000W Generator Owner’s Manual Operation (cont’d) Spark Plug Service Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage In order to service the spark plug, you will need a spark plug wrench (commercially available). capacity (12V DC) is adequate to supply all electrical loads that the unit will power.
  • Page 7: Air Cleaner Service

    Owner’s Manual 4000W Generator Maintenance Guide Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfuncion, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty Periodic maintenance and adjustment is necessary to keep the generator in good operating areas.
  • Page 8: Installation

    Owner’s Manual 4000W Generator Installation (cont’d) Installation Supporting and Mounting NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS Mount the generator on a concrete slab capable of supporting the weight of the generator. The ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL slab must extend on all sides beyond the frame by at least one foot.
  • Page 9 4000W Generator 4000W Generator Cylinder head system assy. Cylinder barrel Description Description APA Part No. APA Part No. APGG4000-A-01-JD CYLINDER HEAD COMP. APGG4000-B-01-JD CRANK CASE APG3012-A-02-JD EX. VALVE GUIDE APG3012-B-02-JD OIL LEVEL SWITCH ASSY. APG3012-A-03-JD IN. VALVE GUIDE APG3012-B-03-JD GOVERNOR GEAR ASSY.
  • Page 10 4000W Generator 4000W Generator Piston and connecting rod system assy. Recoil starter system assy. Description APA Part No. Description APA Part No. APGG4000-E-01-JD COMPRESSION RING A APG3012-F-01-JD PIVOT ADJUSTING NUT APGG4000-E-02-JD COMPRESSION RING B APG3012-F-02-JD ROCKER ARM PIVOT APGG4000-E-03-JD OIL RING A...
  • Page 11 Carburetor system assy. Flywheel system assy. Description APA Part No. APG3012-J-01-JD FLYWHEEL Description APA Part No. APG3012-J-02-JD FLANGE BOLT (M6 X 25) APGG4000-I-01-JD CARBURETOR ASSY. APG3012-J-03-JD COOLING FAN APG3012-I-02-JD CARBURETOR PAPER GASKET APG3012-J-04-JD STARTER PULLEY APG3012-I-03-JD CARBURETOR INSULATING PLATE APG3012-J-05-JD...
  • Page 12: Air Cleaner

    FLANGE NUT (M5) APG3012-O-04-JD AIR CLEANER SEPARATOR APG3012-O-05-JD AIR CLEANER SEAL Description APA Part No. APG3012-O-06-JD AIR CLEANER CASE COMP. APGG4000 -P-01-JD FUEL FILLER CAP COMP. APG3012-O-07-JD GASKET APGG4000 -P-02-JD FUEL FILTER APGG4000 -P-03-JD FUEL TANK COMP. APGG4000 -P-04-JD FUEL METER ASSY.
  • Page 13 4000W Generator 4000W Generator Generator Wheel & Hand Assy. Description APA Part No. APGG4000-S-01-JD STATOR COVER 10 11 APGG4000-S-02-JD STATOR ASSY. APGG4000-S-03-JD COOLING FAN APGG4000-S-04-JD BRUSH ASSY. Description APA Part No. APGG4000-S-05-JD TAPPING SCREW APGG4000-T-01-JD PIN SPLIT APGG4000-S-06-JD GENERATOR STAY...

Table of Contents