5

Operation

5.1
Filling the water tank (PH28 only)
1
Switch off the Defensor PH28 and
disconnect the unit from the mains
(pull the mains plug out of the
socket).
4
Lay down the water tank carriage,
remove the tank cap and fill the tank
with tap water using the supplied
filling hose. Do not use additives.
Relocate the tank cap.
Important! Screw on tank cap until
it comes to a stop!
CAUTION! In order to avoid water
damage, completely remove any
spilled water on the water tank
carriage.
2
Press the snap and fold out the
water tank carriage.
5
Slide the water tank carriage into the
unit, then tip it up to the stop.
3
Pull out the handle and slide the wa-
ter tank carriage out of the unit.
CAUTION! In order to avoid water
damage, immediatelly remove any
spilled water on the floor and on the
components of the unit.
6
Press the lock mechanism of the
handle on both sides of the carriage
and the handle slides down. Tip up
the water tank carriage until the lock
engages. The water now flows into
the base tub.