Fault elimination
7.1

Event messages

Display
Radio sensor K1
Install.? ESC/E
Radio sensor K1
Test
7.2

Warning messages

Display
Warning 6
Filter change
Warning message is alter-
nating with the standard
operating display.
Cause:
Action/Remedy: Replace filter set (see chapter 6 "Maintenance"), then reset warning message.
Warning 7
No water
Warning message is dis-
played until the water level in
the base tub is ok. again.
Note:
Cause:
Action/Remedy: Check/refill water tank.
Warning 8
Battery radio
Warning message is alter-
nating with the standard
operating display.
Cause:
Action/Remedy: Replace battery of the radio humidity sensor (see separate instructions of radio humidity
Description
Cause:
Action:
Cause:
Action:
red LED
lights
Maximum lifetime of the filter set expired.
lights
This message is displayed only on the Defensor PH28
The water level in the base tub is too low, level switch has triggered.
lights
Battery in radio humidity sensor (option) is empty.
sensor).
If a new battery is inserted into the radio humidity sensor (op-
tion) and the radio channel of the radio humidity sensor does
not correspond to the active channel of the Defensor PH28/
PH28A a beep sounds briefly (if the buzzer is activated) and a
new radio channel (e.g. K1) will be proposed.
Press the <Enter> key if you want to confirm the suggested
channel. The Defensor PH28/PH28A switches to the new chan-
nel and returns to the standard operating display.
Press the <ESC> key if you want to reject the suggested channel.
The Defensor PH28/PH28A returns to the standard operating
display and uses the old signal source.
If a new battery is inserted into the radio humidity sensor (op-
tion) and the radio channel of the radio humidity sensor does
correspond to the active channel of the Defensor PH28/PH28A
a beep sounds briefly (if the buzzer is activated) and the unit
confirms the correct channel.
To reset the message and to return to the standard operating
display press the <Enter> or the <ESC> key.
Buzzer
Error relay
–––
activated
–––
activated
beeps briefly
activated
every 30 min-
utes
Resetting
see chapter 6.5.
Automatic resetting as
soon as the water level
in the base tub is at normal
level again.
Automatic resetting after
replacement of the bat-
tery.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ph28a

Table of Contents