A. PUMP DOES NOT OPERATE
1. Check GFCI for proper operation according to
GFCI manufacturer's instructions.
2. Check for plugged impeller. Follow disassembly/as-
sembly instructions under "Pump Service", Page 8.
3. Consult dealer/installer or service representative.
4. Air switch location too far from pump (See Page 6).
B. IMPROPER JET ACTION
1. Check for blocked fittings. Blocked fittings will cause
poor flow and poor jet action.
2. Consult dealer/installer or service representative.

TROUBLESHOOTING GUIDE

C. EXCESSIVE AIR IN SYSTEM – PUMP LOSES
PRIME
1. Make sure water level in spa is at least 2" (51 mm)
above top of jets with system not operating.
2. Make sure there are no leaks in suction piping.
3. Make sure there is no vortex (whirlpool) at the suc-
tion.
4. Consult dealer/installer or service representative.
D. CIRCUIT BREAKER IN HOME PANEL TRIPS
REPEATEDLY
1. Breaker must be of adequate capacity.
2. For GFCI breaker: test according to GFCI manufac-
turer's instructions.
3. Make sure no other lights and appliances are on cir-
cuit.
4. Consult dealer/installer or service representative.