Gas; General Safety Rules For The Use Of Liquid Gas Facilities - Hobby 400 SB Excellent Easy Operation Manual

Hobby camper motor home operation guide
Table of Contents

Advertisement

9. Gas

9.1 General safety rules for the use of liquid gas
facilities
The gas operation pressure is
30 mbar.
Inspection of the gas facilities
Hae the gas facilities checked by an expert
before the first use.
The gas facilities should be inspected by
an expert every two years. This inspection
should be documented on the inspection cer-
tificate in accordance with the German Asso-
ciation of Gas and Water Experts, worksheet
G 607, and EN 949.
Regulator knobs, hoses and waste gas out-
lets should also be inspected.
We recommend that you replace the safety
regulator knob and hose pipes fter 10 years at
the latest.
The owner/operator is responsible for arran-
ging the inspection. This also applies for ve-
hicles that are not licensed to drive on public
roads.
Installations and modifications
Installations and modifications may only be
conducted by an expert.
Only devices with a uniform inlet pressure of
30 mbar may be operated.
Regulator knobs and valves
Only use those regulator knobs custom-made
for vehicles, with a safety valve. Other regula-
tor knobs are not permissible in accordance
with the German Association of Gas and Wa-
ter Experts, worksheet G 607, and EN 949.
They are not sufficient to tolerate the im-
mense strain.
Pressure regulators must have a fixed output
pressure of 30 mbar. The requirements of EN
12864, Appendix D, apply accordingly. The
regulator must have a rate of flow of 1.2 kg/h.
Connections on gas pressure regu-
lators are screwed on counterclock-
wise.
09-

Hide quick links:

Advertisement

Table of Contents