Table 1 - general Data
Ideal Logic Combi
Gas supply
Gas Supply Connection
Injector Size
Inlet Connection
Outlet Connection
Flow Connection
Return Connection
Flue Terminal Diameter
Average Flue Temp-Mass Flow Rate
Maximum Working Pressure (Sealed Systems)
Maximum Domestic Hot Water Inlet Pressure
Minimum Domestic Hot Water Inlet Pressure*
Electrical Supply
Power Consumption
Fuse Rating
Water content
Packaged Weight
Maximum Installation Weight
Boiler Casing Size
*Required for maximum flow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Table 2 - Performance Data - Central heating
Boiler Input :
Boiler Input 'Q'
Nett CV
Gross CV
Gas Consumption
Boiler Output :
Non Condensing
70
C Mean Water temp.
o
Condensing
40
C Mean Water temp.
o
Seasonal efficiency*
Seasonal efficiency*
NOx Classification
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
Note. Gas consumption is calculated using a
calorific value of 38.7 MJ/m
or 34.9 MJ/m
(935 Btu/ft
) nett
3
3
To obtain the gas consumption at a different
calorific value:
a. For l/s
- divide the gross heat input
(kW) by the gross C.V. of the gas (MJ/m
b. For ft
/h - divide the gross heat input (Btu/h)
3
by the gross C.V. of the gas (Btu/ft
c. For m
/h - multiply l/s by 3.6
3
4
Domestic Hot Water
Domestic Hot Water
Central Heating
Domestic Hot Water litre (gal)
Height
Width
Depth
Max.
Min.
24
30
kW
24.3
4.9
6.1
(Btu/h) (82,900) (16,600 (20,700 (24,100)
kW
27.0
5.4
6.7
(Btu/h) (92,000) (18,400) (23,000) (26,900)
m
/h 2.512
0.500
0.627
3
(ft
/h)
(89)
(17.8)
(22)
3
kW
24.2
4.8
6.1
(Btu/h) (82,600) (16,500) (20,700) (24,100)
kW
25.6
5.1
6.4
(Btu/h) (87,400) (17,500) (21,800) (25,500)
SEDBUK 2005
91%
91.1%
SEDBUK 2009
89%
89%
CLASS 5
(1038 Btu/ft
) gross
3
3
)
3
)
3
general
(mm)
Central Heating
Central Heating
mm (in)
(DHW)
63
bar (lb/in
)
2
bar (lb/in
)
2
bar (lb/in
)
0.8 (11.6)
2
W
litre (gal)
kg (lb)
37.7 (83.1)
kg (lb)
32.7 (72.1)
mm (in)
mm (in)
mm (in)
Table 3 - Performance Data - Domestic hot Water
Maximum DHW Input :
35
7.1
Gross CV
7.9
Gas Consumption
0.734
(25.9)
Maximum
7.1
DHW Output
DHW Flow Rate
7.5
at 35°C temp. rise.
DHW Specific Rate
91%
88.9%
Key to symbols
gB =
United Kingdom
PMs = Maximum operating pressure of water
C
C
C
= A room sealed appliance designed for connection via ducts to a
13
33
53
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
= An appliance designed for use on 2nd Family gas, Group H only.
2h
Ideal Logic Combi -
24
30
2H - G20 - 20mbar
15mm copper compression
4.15
4.65
15mm copper compression
15mm copper compression
22mm copper compression
22mm copper compression
100 (4)
C - 11g/s
68
C - 13g/s
o
o
2.5 (36.3)
10.0 (145)
1.3 (18.9)
230 V ~ 50 Hz.
146
152
External : 3A
Internal : T4H HRC L250 V
1.2 (0.26)
0.5 (0.11)
37.8 (83.3)
32.8 (72.3)
700 (27.5)
395 (15.5)
278 (11)
24
Nett CV
kW
24.3
(Btu/h)
(82,900)
kW
27.0
(Btu/h)
(92,000)
m
/h
2.512
3
(ft
/h)
(89)
3
kW
24.2
(Btu/h)
(82,600)
l/min
9.9
(gpm)
(2.2)
l/min
11.5
(gpm)
(2.5)
IE = Ireland
(Countries of destination)
Installation and Servicing
35
4.9
73
C - 15g/s
o
1.3 (18.9)**
177
38 (83.8)
33 (72.8)
30
35
30.4
35.4
(103,600)
(120,900)
33.7
39.3
(115,000)
(134,200)
3.135
3.657
(111)
(129)
30.3
35.3
(103,300)
(120,500)
12.4
14.5
(2.8)
(3.2)
14.5
16.9
(3.2)
(3.7)