Electrical Power Connection

Electrical Power Connection
The ProView is powered by an AC power supply. Grounding of the ProView is provided when
the AC power cable is connected to the unit AC connector.
Grounding Jackscrew
Figure 1: AC Connector
When the ProView is rack-mounted, the device's grounding jackscrew must be connected to
the rack housing, which must be correctly grounded.
DANGER: To avoid electrocution, ensure that the rack has been correctly grounded before switching on
the unit. When removing the unit, remove the grounding connection only after the unit is switched off
and unplugged.
Ground the unit to the grounding jackscrew with cable 18AWG.
CAUTION: This product relies on the building's electrical installation for short-circuit (overcurrent)
protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 20 A U.S. (240 VAC, 20 A
international) is used on the phase conductors (all current-carrying conductors).
ATTENTION: Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit dépend de
l'installation électrique du local. Vérifier qu'un fusible ou qu'un disjoncteur de 120 V alt., 20 A U.S.
maximum (240 V alt., 20 A international) est utilisé sur les conducteurs de phase (conducteurs de charge).
WARNUNG: Dieses Produkt ist darauf angewiesen, daß im Gebäude ein Kurzschluß-bzw.
Überstromschutz installiert ist. Stellen sie sicher, daß eine Sicherung oder ein Unterbrecher von nicht mehr
als 240 V Wechselstrom, 20 A (bzw. in den USA 120 V Wechselstrom, 20 A) an den Phasenleitern (allen
stromführenden Leitern) verwendet wird.