3-2. Function list

GB-24A requires a license registration. By registering the license, group or block operation via the Web
browser will be permitted. License registration that permits various functions can be completed on the
license registration page.
Item
Start/stop
Operation mode
Temperature setting
Air velocity
Air direction
Start/stop of interlocked
equipment (Lossnay)
Prohibition of local control Selecting the items for which local control is prohibited collectively or for each
Hold
Error display
Filter sign display and
reset
Malfunction history
Annual/weekly schedule
Malfunction e-mail history
* The above specification may be changed depending on the equipment connected or combined.
* The block setting and the registration of block/group names require the initial setting web.
* Without prior notice, the content may be changed.
The table below the types of connectable units. Depending on the model and type, not all functions may be
available.
Model
CITY MULTI
LOSSNAY
Mr. Slim
Room air conditioner
Table 3-2. Web monitoring functions
Switching start/stop collectively or for each group
Switching cool/dry/fan/auto/heat/setback collectively or for each group
Setting room temperature collectively or for each group
Set temperature range Cool/dry: 67ºF-87ºF /19ºC-30ºC
Switching air velocity in four steps collectively or for each group.
Switching in four steps vertically and for swing, keep for each group
(Selectable air direction depends on the indoor unit model)
Switching start (Hi/Lo)/stop collectively or for each group when connecting with
interlocked equipment (Lossnay).
(However, ventilation mode can not be selected for the interlocked equipment.)
group.
(Items include start/stop, operation mode, temperature setting and filter sign.)
Prohibits the scheduled operation from being executed.
Identifies the unit and displays the error.
Filter sign display can be reset in each group or collectively.
Malfunction history can be check up to 64 contents in both unit and
communication error.
Using the annual/weekly schedule function by license registration.
E-mail history can be check up to 64 contents.
Requires a M-NET adapter
Content
Heat:
63ºF-83ºF /17ºC-28ºC
Auto:
67ºF-83ºF /19ºC-28ºC
Setback: Upper limit:
Lower limit:
*Note: Preset temperature range varies on different models.
Notes
5
67ºF-87ºF /19ºC-30ºC
53ºF-79ºF /12ºC-26ºC

Advertisement

loading