50
C
4: C
HAPTER
ONNECTORS AND
V.35 DTE Cable
Pinouts
C
ABLES
This cable connects the bridge/router to a V.35 DCE.
Figure 22 Flex-WAN and V.35 DTE Connectors
To SuperStack II NETBuilder
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 32 33
34 35 36 37
38 39 40 41 42 43 44 45
60 59 58 57 56 55 54 53 52 51 50 49 48 47 46
60-pin Flex-WAN connector
Table 14 V.35 DTE Cable Pinouts
Flex-WAN Connector
Signal
Pin
SD/RD-
17
SD/RD+
18
SCTE/SCT-
19
SCTE/SCT+
20
TxC/RxC-
23
TxC/RxC+
24
RxC/TxCE-
25
RxC/TxCE+
26
RxD/TxD-
27
RxD/TxD+
28
DCD/LL
33
DSR/DTR
34
CTS/RTS
35
RTS/CTS
42
DTR/DSR
43
LL/DCD
44
Circuit Ground
45
Shield Ground
46
Shorting Group 1
48
49
Shorting Group 2
50
51
52
Shorting Group 3
53
54
55
56
* Unused twisted wires of a twisted pair should be connected to Shield Ground. In this cable this
is one wire of each of the twisted pairs 6 to 12.
To DCE
V.35 male connector
V.35 DTE Connector
Direction
Pin
Signal
Q
SD-
P
SD-
W
SCTE-
U
SCTE+
AA
SCT-
Y
SCT+
X
SCR-
V
SCR+
T
RD-
R
RD+
F
RLSD
E
DSR
D
CTS
C
RTS
H
DTR
K
LT
-
B
Ground
Cable Shield
A
Shield Ground
-
-
-
-
-
-
-
-
-
Twisted Pair
*
1
2
3
4
5
6
7
8
9
10
11
12
-
-
-
-

Advertisement