Potterton EC three 125 Installation, Operation And Maintenance Manual page 68

Floor standing condensing gas boilers 125 to 300kw
Table of Contents

Advertisement

Programming
Function
Relay output QX22 module 3
Parameters see Relay output QX1 (prog.-no. 5890)!
Relay output QX23 module 3
Parameters see Relay output QX1 (prog.-no. 5890)!
Sensor input BX21 module 1
Parameters see Sensor input BX1 (prog.-no. 5930)!
Sensor input BX22 module 1
Parameters see Sensor input BX1 (prog.-no. 5930)!
Sensor input BX21 module 2
Parameters see Sensor input BX1 (prog.-no. 5930)!
Sensor input BX22 module 2
Parameters see Sensor input BX1 (prog.-no. 5930)!
Sensor input BX21 module 3
Parameters see Sensor input BX1 (prog.-no. 5930)!
Sensor input BX22 module 3
Parameters see Sensor input BX1 (prog.-no. 5930)!
Function input H2 module 1
None | Optg mode change HCs+DHW | Optg mode changeover DHW |
Optg mode changeover HCs | Optg mode changeover HC1 | Optg
mode changeover HC2 | Optg mode changeover HC3 | Heat genera-
tion lock | Error/alarm message | Consumer request VK1 | Consumer
request VK2 | Consumer request VK3 | Excess heat discharge | Release
swi pool solar | | Operating level DHW | Operating level HC1 | Operat-
ing level HC2 | Operating level HC3 | Room thermostat HC1 | Room
thermostat HC2 | Room thermostat HC3 | Limit thermostat HC | Start
prevention | Consumer request VK1 10V | Consumer request VK2 10V
| Consumer request VK3 10V | Preselected output 10V
Contact type H2 module 1
NC | NO
Voltage value 1 H2 module 1
Funct value 1 H2 module 1
Voltage value 2 H2 module 1
Funct value 2 H2 module 1
Function input H2 module 2
Parameters see Function input H2 module 1 (prog.-no. 6046)!
Contact type H2 module 2
NC | NO
Voltage value 1 H2 module 2
Funct value 1 H2 module 2
Voltage value 2 H2 module 2
Funct value 2 H2 module 2
Function input H2 module 3
Parameters see Function input H2 module 1 (prog.-no. 6046)!
Contact type H2 module 3
NC | NO
Voltage value 1 H2 module 3
Funct value 1 H2 module 3
Voltage value 2 H2 module 3
68
Condensing gas boiler Eurocondense three125-300 kW
Prog.
Standard value
1)
Level
no.
6037
C
None
6038
C
None
6040
C
None
6041
C
None
6042
C
None
6043
C
None
6044
C
None
6045
C
None
6046
C
None
6047
C
NO
6049
E
0 Volt
6050
E
0
6051
E
10 Volt
6052
E
100
6054
C
None
6055
C
NO
6057
E
0 Volt
6058
E
0
6059
E
10 Volt
6060
E
100
6062
C
None
6063
E
NO
6065
E
0 Volt
6066
E
0
6067
E
10 Volt
7308536-02 06.13