TIMER
PRESELECTION
CREDIT
MANAGEMENT
22
OVERPAY TIME
000
SCALING FACTOR
0
DECIMAL POINT
000.00
This menu sets the overpay time: time limit beyond which the
amount present in the machine is cancelled and saved in the
control data as "Overpay Value".
Value Range: 0 - 255 seconds (0 = Deactivated)
It may be used only when the credit is inserted by means of
the coiner and behaves in the following way:
Multivend deactivated: the credit inserted and not used
within the time limit is cancelled and is saved in the control
data as "Overpay Value".
Multivend activated: the remaining credit is available
for later sales until the overpay time runs out, after which
the remaining credit will be cancelled and saved in the control
data as "Overpay Value".
Every time that a coin is inserted in the coiner or a product is
dispensed, the overpay time restarts the count.
This menu sets the minimum unit that the machine manages
notwithstanding the decimals (range: 1, 10, 100, standard
1). E.g.: In Euro use the scale factor 1.
This menu sets the position of the decimal point: if the setting
is different from the decimal point setting of the card reader,
the coffee machine locks and the following error message
appears on the display:
"MDB READER
"
"DECIMAL ERROR"