Page 1
K R A ME R E LE CT R O N IC S L T D . USER MANUAL MODELS: 616T Dual-Link Detachable Optical DVI Transmitter 616R Dual-Link Detachable Optical DVI Receiver P/N: 2900-300250 Rev 1...
Connecting the Dual-Link Detachable Optical DVI System Avoiding Pitfalls During Operation Technical Specifications Figures Figure 1: The Auto EDID Button on the 616T Figure 2: Connecting the Fiber Optic Cables Figure 3: Connecting the 616T/616R Dual-Link Detachable Optical DVI Transmitter/Receiver 616T, 616R – Contents...
Room Connectivity; GROUP 10: Accessories and Rack Adapters and GROUP 11: Sierra Products. Congratulations on purchasing your Kramer 616T Dual-Link Detachable Optical DVI Transmitter and 616R Dual-Link Detachable Optical DVI Receiver, which are ideal for the following typical applications: •...
• Do not secure the cables in tight bundles or roll the slack into tight coils • Position your Kramer 616T, 616R away from moisture, excessive sunlight and dust Caution: No operator serviceable parts inside the unit...
500 meters (1640 feet) over duplex multimode fiber optic cable with two LC connectors. The 616T converts dual link DVI signals to optical signals that it transmits to the 616R. The 616R decodes the optical signals back to a dual link DVI signal.
Powering the 616T and the 616R Your 616T/616R pair comes with two 5V DC power adapters. The 616R module must always be powered by the power adapter. The 616T can be powered either by an external power adapter or internally from the 5V pin on the DVI card of the computer.
4.3) C apturing the EDID The 616T and 616R are connected via one dual link channel. The EDID of the display device is captured by the transmitter for the computer to read. The factory default EDID is set to WQXGA (2560x1600). If your display has this resolution, you do not need to capture the EDID.
1. Capture the EDID of the display device (see Section 4.1). 2. Connect the 616R to the 5V DC power adapter and connect the adapter to the mains electricity. The LED lights. 3. Connect the duplex LC fiber cable to the 616T and 616R modules, one...
After completing the installation, if the system does not seem to work properly, reconnect the power adapter while the system is powered. Figure 3: Connecting the 616T/616R Dual-Link Detachable Optical DVI Transmitter/Receiver 616T, 616R - Using the Dual-Link Detachable Optical DVI System...
XGA resolution) • Reset the system • Disconnect and reconnect the optical DVI cables Be sure that at all times the cables are stored and used away from liquid or dirt. 616T, 616R - Using the Dual-Link Detachable Optical DVI System...
WQUXGA, 33Hz (XGA is not supported) MAX. RANGE: 500m (1640ft) for WQUXGA (3840x2400) at 33Hz refresh rate. POWER CONSUMPTION: 5V DC, 430mA max. (616T); 350mA max. (616R) OPERATING TEMPERATURE: 0° to +40°C (32° to 104°F) STORAGE TEMPERATURE: -40° to +70°C (-40° to 158°F)
Page 14
For the latest information on our products and a list of Kramer distributors, visit our Web site where updates to this user manual may be found. We welcome your questions, comments, and feedback. Web site: www.kramerelectronics.com E-mail: info@kramerel.com SAFETY WARNING...