5. Required Tools and Equipment

Screwdriver – 3.5mm flat
Side cutter
Drill bits – 5mm masonry; 6mm drill bit
Silicone sealant
Fasteners and rawl plugs
Six metres of n6 core communication cable

6. Mounting Instructions

Important Considerations
All users calling or sending an SMS to the Module need to ensure that their Caller Line
Identification Presentation (CLIP) is activated on their phone to ensure that the
Module recognises the user's learned-in phone number
If a contract SIM card is being used in the Module itself, CLIP must also be enabled on
that SIM card. This can be done by first inserting the SIM card into a mobile phone
and enabling CLIP
Ensure that the SIM card in the GSM Module does not have Call Forwarding enabled
The SIM card in the GSM Module must have the PIN (Personal Identification Number)
code disabled

Calling Module Mounting

Wall mounting recommendations
Position the Calling Module on
wall adjacent to entrance gate or
door
Mount at a height that allows for
comfortably speaking into the
microphone
A typical recommended height is
shown in Figure 5
Gooseneck mounting recommendations
Ensure that the Calling Module
does not protrude too far into
the driveway
The Calling Module must not be
set too far back and must be
easily accessed from a vehicle
The height should allow for
comfortably speaking into the
microphone
Calling
Module
page 10
FIGURE 5.
Calling
Module
FIGURE 6.