Setup

Setup Machine
The following machine parameters should be set upon placement of machine for product turn over.
□ Set Thickness (Product consistency)

□ Set Date Time

□ Set Language
□ Set Night Time
□ 6 Month PM (Recommended)
□ Day To Clean (Recommended)
LAF Set Up Menus
□ Delayed Refill
□ Enable Refill ? (Ultra-1 Only)

Set Thickness

Setting the thickness changes the ice consistency, or torque of each auger. The factory default is 8 with a range of 1
to 16.
Step 1: Press and hold the Gourmet switch until the display screen reads "Cleaning Guide?".
Step 2: press and release the Gourmet switch until the "Set Thickness?" option is shown in the display screen.
Step 3: Select Yes (Ice) to access the Set Thickness option.
Step 4: Use Min (-) and Max (+) to adjust the thickness levels. Press the Gourmet switch to accept the desired set-
ting for the left side.
Step 5: Use the same controls to adjust the thickness level for the right side. Press the Gourmet switch to accept the
desired setting.
Step 6: Press Next (Gourmet) until you exit programming and return to the Home Screen.
Set Date Time
Allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display on the Home Screen.
Step 1: Press and hold the Gourmet switch until the display screen reads "Cleaning Guide?".
Step 2: Press and release the Gourmet switch until the "Date/Time" setting option appears in the display screen.