Never touch the internal parts of the remote
controller.
Do not remove the front panel. Touching certain
internal parts will cause electric shocks and
damage to the unit. Please consult your dealer
about checking and adjustment of internal parts.
Do not leave the remote controller wherever
there is a risk of wetting.
If water gets into the remote controller there is a
risk of electrical leakage and damage to elec-
tronic components.
• NOTE TO SURVICE PERSONNEL
CAUTION
Read the following for the safety.
Do not operate the unit while the suction grille is
open.
• Fan may rotate and cause accident.
Make sure to screw the suction grille stopper.
• If the screw is not completely tightened, the suc-
tion grille may come off and you may cut your fin-
gers with the fan.
• After the installation or service maintenance,
make sure to put the grille stopper to where it was
with screws.
(R & L, total 2:see the below.)
Grille fixture
Front panel
Tapping screw
Suction grille
WARNING
May cause electric shock, ignition, fire
• Before starting the inspection of the electrical
parts (control box, fan motor, drain pump, etc.),
be sure cut off the all air-conditioner power (adap-
tor for wiring power is included) or you may get an
electric shock.
• When cleaning the heat exchanger, be sure to
remove the switch box, fan motor and drain
pump.
Water or detergent may deteriorate the insulation
of electric components and result in burn-out of
these components.
4
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING
RZQG
Grille stopper
RZQSG71·
100·125·
140
HEATING
RZQG
RZQSG71
RZQSG100·
125·140
D B: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote con-
troller is 16°C to 32°C.
CAUTION! ELECTRIC SHOCK
• Due to high voltage, do not open control box lid for
ten minutes after the safety breaker is switched
off.
• After the box is opened, measure the voltages of
the points shown below printed circuit board with
a tester and confirm that the voltages are not
higher than DC50V.
Do not touch live parts when carrying out this work.
Residual voltage
measurement points
0
-
• After power failure, operation will restart automat-
ically.

3. OPERATION RANGE

INDOOR
OUTDOOR
TEMPERA-
UNIT
TURE
DB 18 to 37
WB 12 to 28
DB 21 to 37
WB 14 to 28
INDOOR
OUTDOOR
TEMPERA-
UNIT
TURE
10 to 27
DB
10 to 30
DB
DB
10 to 28
Control box
Printed circuit board
- C
+
C
+
OUTDOOR
TEMPERA-
HUMI-
TURE
DITY
80% or
DB –15 to 50
below
80% or
DB –10 to 43
below
OUTDOOR
TEMPERATURE
–19.5 to 21
DB
–20 to 15.5
WB
– 14 to 21
DB
–15 to 15.5
WB
– 14 to 21
DB
–15 to 15.5
WB
English
[°C]
[°C]