    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Deutsch MODELS Français (Floor standing type) FVQ71CVEB Español FVQ100CVEB FVQ125CVEB FVQ140CVEB Italiano Nederlands Portugues...
  • Page 2 τηλεχειριστηρίου. Επιπλέον, μην παραλείψετε να παραδώσετε αυτό το εγχειρίδιο λειτουργίας σε έναν νέο χρήστη, όταν αυτός Vielen Dank für den Kauf einer Klimaanlage von Daikin. θα αναλάβει τη λειτουργία της μονάδας. Αυτό το εγχειρίδιο Lesen Sie dieses Betriebshandbuch vor Inbetriebnahme προορίζεται...
  • Page 4 DISPOSAL REQUIREMENTS VORSCHRIFTEN ZUR ENTSORGUNG INSTRUCTIONS D’ÉLIMINATION ΠΡΟŸΠΟΘΕΣΕΙΣ ΑΠΟΡΡΙΨΗΣ REQUISITOS PARA LA ELIMINACIÓN SPECIFICHE DI SMALTIMENTO VEREISTEN VOOR HET OPRUIMEN REQUISITOS PARA A ELIMINAÇÃO ТРЕБОВАНИЯ К УТИЛИЗАЦИИ BERTARAF GEREKSINIMLERI Προϋποθέσεις απόρριψης Disposal requirements Το κλιματιστικό σας επισημαίνεται με αυτό το σύμβολο. Αυτό σημαίνει ότι οι ηλεκτρικές και Your air conditioning product is marked with this symbol.
  • Page 5: Table Of Contents

    The unit is individually operated. Refrigerant type:R410A NOTE value:1975 • Contact your Daikin dealer in case of changing the combination or setting of group control and GWP = global warming potential two remote controller control systems. Periodical inspections for refrigerant leaks may be •...
  • Page 6: Safety Precautions

    on the air conditioner after the qualified service 2. SAFETY PRECAUTIONS person confirms that the leakage is repaired. To gain full advantage of the air conditioner’s func- Consult your local dealer regarding what to tions and to avoid malfunction due to mishandling, do in case of refrigerant leakage.
  • Page 7 Using the product in such places may cause fire Do not place appliances that produce naked or product failures. flames in places exposed to the airflow from the unit as this may impair combustion of the Do not use flammable materials (e.g., hair- burner.
  • Page 8: Operation Range

    Never touch the internal parts of the remote CAUTION! ELECTRIC SHOCK controller. • Due to high voltage, do not open control box lid for Do not remove the front panel. Touching certain ten minutes after the safety breaker is switched internal parts will cause electric shocks and off.
  • Page 9: Installation Site

    • Operating procedure varies with heat pump type around? and cooling only type. Contact your Daikin dealer to confirm your system type. • Do not use the air conditioner in the following • To protect the unit, turn on the main power switch places.
  • Page 10 DEFROST OPERATION (Frost removal oper- NOTE ation for the outdoor unit) • If the temperature is excessively lowered, switch • As the frost on the coil of an outdoor unit increase, to the COOLING OPERATION once, and then heating effect decreases and the system goes stop the operation.
  • Page 11: Optimum Operation

    Movement of left and right airflow flaps Horizontal flaps • For the following conditions, micro computer con- Upper flaps trols the airflow direction so it may be different from the display. Interlocking flaps for • When the set temperature is higher than the group No.2 (×4) indoor temperature (HEATING OPERATION).
  • Page 12: Maintenance (For Service Personnel)

    • Adjust the room temperature properly for a com- 8. MAINTENANCE fortable environment. Avoid excessive heating or (FOR SERVICE PERSONNEL) cooling. Not doing so wastes electricity. ONLY A QUALIFIED SERVICE PERSON IS • When the display shows “ ”, ask a qualified ALLOWED TO PERFORM MAINTENANCE service person to clean the filters.
  • Page 13 1. Unlock the suction grille. Remove water and dry in the shade. Pull up the lock lever to unlock it. NOTE • Do not wash the air conditioner with water which is 50°C or more, as doing so may result in discol- oration and/or deformation.
  • Page 14: Not A Malfunction Of The Air Conditioner

    [CLEANING BEFORE AND AFTER SEA- 9. NOT A MALFUNCTION OF THE SONAL USE] AIR CONDITIONER START UP AFTER A LONG STOP The following symptoms do not indicate air condi- Confirm the following tioner malfunction • Check that the air inlet and outlet are not blocked. Remove any obstacle.
  • Page 15 It is necessary to clean • Even if the fan speed control button is the inside of the indoor unit. Ask your Daikin pressed, the fan speed does not change. dealer for details on cleaning the unit. This oper- During the COOLING OPERATION, the airflow ation requires a qualified service person.
  • Page 16: Trouble Shooting

    If the air filter is clogged, the airflow rate will set temperature. drop and as a result the performance will also For details, contact your Daikin dealer. drop. In addition, this may cause dew condensation X. THE UNIT DOES NOT COOL EFFECTIVELY.
  • Page 17 CODE Turn off the ON/OFF timer. • Are you sure that a remote control device is not Measure: Notify your Daikin dealer and inform connected? him/her of the display. Contact the central control room that directed the stop.
  • Page 18 3P170549-14J EM11A037A (1201) HT...