Take out the contents of the cooling device.
➤
If necessary, place them in another cooling device to keep them
cool.
➤
Switch off the device.
➤
Leave the cover open.
➤
Wipe off the defrosted water.
6.10
Replacing the device fuse (240V)
Only CF-35, CF-40, CF-50, CF-60
Caution – Danger of electrocution!
Disconnect the connection cable before you replace the device fuse.
➤
Pull off the connection cable.
➤
Pry out the fuse insert (Fig.
➤
Replace the defective fuse with a new one that has the same
rating (T4,0AL 250V).
➤
Press the fuse insert back into the housing.
6.11
Replacing the plug fuse (12/24 V)
➤
Pull the adapter sleeve (Fig.
➤
Unscrew the screw (Fig.
housing (Fig.
➤
Carefully raise the upper half of the housing from the lower
(Fig.
➤
Take out the contact pin (Fig.
➤
Replace the defective fuse (Fig.
has the same rating (8A 32V).
➤
Re-assemble the plug in the reverse order.
9
1, page 6).
9
6, page 6) half.
6
2, page 5) with a screwdriver.
9
4, page 6) off of the plug.
9
5, page 6) out of the upper half of the
9
3, page 6).
9
2, page 6) with a new one that
CoolFreeze
21