Installation Instructions
INSTALLATION
INSTRUCTIONS
IMPORTANT
IMPORTANT:
Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
D
NOTE: "D" is clearance needed for unit depth measure down from top of countertop. Typical for all units.
UNITS PROVIDED WITH 1/2 (1.3 cm) I.D. FLEXIBLE CABLE 48 (121.9 cm) LONG WITH 6 (15.2 cm) WIRE LEADS
AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240 VOLT ELECTRICAL SERVICE).
INSTRUCTIONS TO
S Side and Back Wall Clearance: Unit may be safely installed as near as 2 1/2 inches (6.35 centimeters) from side
walls and 3/4 inch (1.91 centimeters) from back wall.
Notice To Installer: Leave these instructions with the appliance.
Notice To Consumer: Retain these instructions for future reference.
A–4
Radiant Cooktop
Models JEC0530 & JEC0536
- SAVE FOR THE LOCAL ELECTRICAL INSPECTOR'S USE
(Dimensions shown in both inches and centimeters)
INSTALLER:
FOUR-ELEMENT RADIANT COOKTOPS
A
B
C
D
E
F
G
FIGURE 1
FIVE-ELEMENT RADIANT COOKTOPS
A
B
C
D
E
F
G
FIGURE 2
16023537
403 WEST FOURTH STREET, NORTH D NEWTON, IA 50208
JEC0530
DIMENSIONS
inches
29-1/16 + 1/16
74.0 + 0.2
20-3/8 + 1/16
51.9 + 0.2
2-1/8
4-1/4 min. clear
29-15/16
21-1/2
3-5/8
JEC0536
DIMENSIONS
inches
34-9/16 + 1/16
87.9 + 0.2
20-3/8 + 1/16
51.9 + 0.2
2-1/8
4-1/4 min. clear
35-5/16
21-1/2
3-5/8
IMPORTANT
CUTOUT
DIMENSIONS ARE
CRITICAL
8101P645-60
©2004 Maytag Services
cm
5.4
10.8
76.0
54.6
7.6
cm
5.4
10.8
89.7
54.6
7.6
(03-04-00)