Chamberlain Elite EL25 Programming Manual page 58

Hide thumbs Also See for Elite EL25:
Table of Contents

Advertisement

Set Visitor Talk Time:
This feature sets the amount of time a visitor and resident may talk before the unit breaks communication.
The unit will beep 10 seconds prior to terminating a call. The resident may press " 1 " to reset the timer and
extend their talk time.
1 Press
Then
2 Enter Number of Seconds (15-250). Then (
Set "Standard Single Ring" or "Double Ring" Response:
A "Double Ring every 6 seconds" can be used instead of the standard single ring when a visitor contacts the
resident through the EL25.
1 Press
Then
2 Standard Single Ring (0) or Double Ring (1). Then (
Set Maximum Number of Rings Allowed Before Aborting Attempt:
Set maximum ring count (1-9) before unit will abort visitor's call attempt.
1 Press
Then
2 Enter Maximum Ring Count Allowed (1-9). Then (
Press
***
Exiting programming mode allows changes to take effect
If you make an error during an entry, press the asterisk key (
5
Factory Setting: 60 seconds
#
)
Factory Setting: "0" Standard Single Long Ring
#
)
)
#
To enter programming mode from the EL25:
and the 6-Digit Password (2 short beeps will be heard)
Page 57
Example:
Sets the maximum time a visitor can talk
with a resident to "50" seconds.
15
Example:
Sets the visitor ring to double. The phone
will ring twice every six seconds during a
visitor call.
14
Factory Setting: 5 Rings
Example:
Sets the maximum number of rings to "7".
) to begin again.
*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents