Configure "Door Forced Open" Alarm Feature:
When enabled, doors that are forced open will trigger an alarm. The alarm will activate the relays you
specify. The relays can remain active until the relay time expires or until the alarm condition clears.
Factory Setting: Disabled
1 Press
2 Enter Alarm Option (0-2). Then (
Option 0 = Disabled
Option 1 = Enabled Relays will activate until relay time expires
(See Set Relay Activation Time on page 21 (Step 3) for more information)
Option 2 = Enabled Relays will activate until the alarm condition clears
3 Activate (1) or Deactivate (0) Relays (0000-1111). Then (
Example:
When a "Door Forced Open" alarm condition occurs, relay "4" will activate until the relay condition expires.
If the alarm relay controls a siren, the siren will sound until the relay time expires.
Setting "Strikes and Out" (Number of Entry Code Attempts before Disabling Unit):
The "Strikes and Out" feature prohibits unauthorized persons from guessing an entry code or the unit
password and entering programming mode. Anyone entering an entry code or password will have a set
number of times to correctly enter their code. Each time the code is entered erroneously, it is a "strike".
After "x" number of "strikes", the system will disallow code entry at the unit for 3 minutes.
Factory Setting: 3 Times
1 Press
Then
2 Enter Maximum Number of Strikes and Outs Allowed (0-5). Then (
0 = Disabled
Configure "Strikes and Out" Alarm Feature:
When enabled, an alarm will trigger if someone enters an erroneous entry code or the unit password on the
unit keypad more than the maximum number allowed (see above). The alarm will activate the relays you
specify. The relays can remain active until the relay time expires or until the alarm condition clears.
Factory Setting: Disabled
1 Press
2 Enter Alarm Option (0-2). Then (
Option 0 = Disabled
Option 1 = Enabled Relays will activate until relay time expires
(See Set Relay Activation Time on page 21 (Step 3) for more information)
Option 2 = Enabled Relays will activate until the alarm condition clears
3 Activate (1) or Deactivate (0) Relays (0000-1111). Then (
Example:
When a "Strikes and Out" alarm condition occurs, relay "4" will activate until the relay time expires.
103
Then
)
#
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
1
104
Then
)
#
(1st digit=Relay 4, 2nd digit=Relay 3, etc.)
1
Page 51
#
)
Relay 4
Relay 3 Relay 2 Relay 1
Activate
Deact Deact Deact
2
)
#
#
)
Relay 4
Relay 3 Relay 2 Relay 1
Activate
Deact Deact Deact
2
3
17
3

Hide quick links: