Installation Instructions If you have questions, call 800.GE.CARES or visit our website at: monogram.com Island Vent Hoods Models: ZV42I ZV54I...
Safety Information READ AND SAVE THESE INSTRUCTIONS BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK OF Read these instructions completely and carefully. FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: IMPORTANT • Save these instructions for A. Use this unit only in the manner intended local inspector’s use.
• Une quantité d’air suffisante est nécessaire à une Pour les services locaux Monogram dans votre secteur, combustion et une évacuation appropriées des gaz par le conduit d’évacuation (cheminée) de Pour les services Monogram au Canada, appelez le l’équipement à...
These accessories include telescoping support • When installing these Island Hoods above a frames and decorative covers. Order the accessory Monogram Professional Range or Cooktop, for your model at the same time as the vent hood installation clearance must be at least 30”.
Advance Planning ADVANCE PLANNING POWER SUPPLY Ductwork Planning IMPORTANT - (Please read carefully) WARNING: • These vent hoods are equipped for 10” round ductwork. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE • Determine the exact location of the vent hood. PROPERLY GROUNDED.
Duct Cover Countertop 8’10” 8’9” 8’8” 8’7” ACCESSORIES 8’6” 8’5” ZX42DC10 – Optional Accessory for ZV42I. 8’4” Supplied ZX54DC10 – Optional Accessory for ZV54I. 8’3” Support Accessories for ceiling heights of 8’6” to 10’4”. 8’2” 8’1” Includes telescoping support frames and duct Duct Cover 8’...
Advance Planning DUCT FITTINGS Equivalent Quantity Total Duct Piece Length* Used Length 10” round Use this chart to compute maximum to 8” round 5 ft. permissible lengths for duct runs to outdoors. Round, 1 ft. For best results, use 10” diameter duct. straight (per foot Note: Do not exceed maximum permissible...
Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. Allen Wrench Support frame for 8 ft. ceiling Transition with Damper with 4 large pan head screws installed on the bottom corners. Implement rods with standoffs 2-piece decorative duct cover Duct collar Decorative top cover 2 Filters (3 with 54”...
Installation Instructions Plan the Location of the Hood and Ductwork • The hood should extend beyond the front and rear • Use a plumb bob to check the location. The edge of the cooking appliance. countertop/cooktop below the hood must be centered •...
Page 12
Installation Instructions CONTINUED 12-3/4” (42” EXAMPLE B Hood) 17” (54” Hood) Install Cross-Framing 16” Joist Symmetrically Spacing About Duct/ Cooktop Centerline 2x4 Cross Framing 8 5/8” Front Cooktop Align duct Hood Outline to center of Cooktop Top View – Ceiling Joists Run Perpendicular to Front of Hood EXAMPLE C 12-3/4”...
Page 13
Installation Instructions CONTINUED • Secure each 2 x 4 block with at least four (4), #10 2x 4 Min. Cross Framing wood screws, 3” long (not supplied). Use 8 wood screws total for the two supports. • The cross framing must be accurately aligned to assure correct positioning of the hood.
Installation Instructions • Select the template for your hood size. • Align the template with the marks on the ceiling and tape in place. – Be sure the template is oriented correctly, with the front of the hood. • Use a plumb to check to be sure the mount- ing holes will provide parallel alignment with the countertop below.
Installation Instructions INSTALL ACCESSORY (OR SUPPLIED) SUPPORT AND DUCT COVERS Install Small Pan Hea Screws on Each Side Top Duct Cover Screws D Bottom Duct Cover Adjust Install Frame to Install Stop Safety Screw nstallation Screw on Each Side Height Screws E Stop Screw Storage Location...
Installation Instructions INSTALL HOOD WITH DAMPER Note: THREE PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION! Bumper Pads Duct Transition 1/4" Gap Attachment Attachment Keyholes Screws Screws C • Back out the hanging screws on the bottom of the support frame to a 1/4” gap. IMPORTANT: Remove shipping tape from damper •...
Installation Instructions CONNECT ELECTRICAL Verify that power is turned off at the source. • Install strain relief onto the knockout of the junction box. WARNING: If house wiring is not 2-wire • Insert house wiring through strain relief and tighten. with a ground wire, a ground must be provided by •...
Installation Instructions INSTALL RODS SKIP THIS STEP IF USING THE SUPPLIED DUCT • Use a flat blade screwdriver to install stand-offs COVER into the bottom of the hood. • Align implement rod to stand-offs with the screw • Hold the duct cover in place and remove the hole towards the inside of the hood.
Installation Instructions INSTALL SUPPLIED DUCT INSTALLATION CHECKLIST COVER AND TOP COVER Check Blower Safety Screw Ensure that blower safety screw is securely tight- Install Duct ened. See page 16, Step 9. If screw is missing, order Cover Screw replacement parts bag. on Each Side Screws D Check Operating Sound and Proper Air-Flow...
Page 20
Note: While performing installations described in this book, safety glasses or goggles should be worn. For Monogram local service in your area, call ® 1.800.444.1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and speci- fications are subject to change without notice.