Operating Instructions
Interconnect Feature
IMPORTANT: This unit is only approved to interconnect with the
Kidde line of products. It is not approved to interconnect with
any other manufacturer's products.
• When compatible smoke alarms and heat alarms are
interconnected to this alarm, they will only respond to a
smoke related event.
• When mixing compatible models with battery backup with
models without battery backup, be advised that the models
without battery backup will not respond during an AC power
failure.
• This unit is only approved to interconnect with other Kidde
products. It is NOT approved to interconnect with any other
brand of detection product.
• This alarm is interconnect compatible with the following
alarms and accessories:
Smoke Alarms: 1235CA, 1275CA, 1276CA, 1285CA,
i12020CA, i12020ACA, i12040CA, i12040ACA, 12060CA,
i12060ACA, KN-SMFM-I-CA, PE120CA, P12040CA, Pi2000CA,
Pi2010CA
CO alarms: KN-COB-ICB-CA, KN-COB-IC-CA, KN-COP-IC-CA
Combo alarms: KN-COSM-ICA, KN-COSM-IBCA,
KN-COSM-IBACA, KN-COPE-ICA
Heat alarm: HD135F
Relay modules: SM120X, CO120X
Strobe Light: SL177i, SLED177iCA
For more information about compatible interconnect units and
their functionality in an interconnect system, visit our web site
at: www.kiddecanada.com
Smoke HUSH
The HUSH feature has the capability of temporarily desensitizing
the smoke alarm circuit for approximately 9 minutes. This
feature is to be used only when a known alarm condition, such
as smoke from cooking, activates the alarm. When the unit is in
alarm you can put your Smoke/CO Alarm in HUSH mode by
pushing the test/reset button. If the smoke is not too dense, the
alarm will silence immediately, the unit will verbally announce
"HUSH MODE ACTIVATED", and the green LED will flash every
2 seconds for approximately 9 minutes. This indicates that the
smoke alarm is in a temporarily desensitized condition.
®
Control Feature