• If the alarm is located outside the bedroom or on a different
floor, it may not wake up a sound sleeper.
• The use of alcohol or drugs may also impair one's ability to
hear the smoke alarm. For maximum protection, a smoke
alarm should be installed in each sleeping area on every level
of a home.
• Although smoke alarms can help save lives by providing an
early warning of a fire, they are not a substitute for an
insurance policy. Home owners and renters should have
adequate insurance to protect their lives and property.
Carbon Monoxide (CO) Alarm
The Carbon Monoxide (CO) alarm monitors the air for the
presence of CO. It will alarm when there are high levels of CO
present, and when there are low levels of CO present over a
longer period of time (see below for alarm times). When a CO
condition matches either of these situations, the alarm/voice
message warning system will sound, and be accompanied by
the flashing red LED light. The carbon monoxide sensor uses an
electrochemical technology.
!
CAUTION: This alarm will only indicate the
presence of carbon monoxide gas at the sensor.
Carbon monoxide gas may be present in other areas.
Individuals with medical problems may consider using warning
devices which provide audible and visual signals for carbon
monoxide concentrations under 30 ppm.

CO Alarm Response Times

Never restart the source of a CO problem until it has
been fixed. NEVER IGNORE THE ALARM!
The CO sensor meets the alarm response time requirements as follows:
At 70 PPM, the unit must alarm within 60-240 minutes.
At 150 PPM, the unit must alarm within 10-50 minutes.
At 400 PPM, the unit must alarm within 4-15 minutes.