Procedure:
Enter the PGM2-Mode as previously outlined
1. Enter 2690
.
2. Depress [
] key
3. Depress [@/FOR] key
4. Enter 1
5. Depress [@/FOR] key
6. Enter assigned channel numbers ( 4 digits)
7. Depress [SBTL] key
8. Depress the [CA/AT] key
Channel Assignment for COIN DISPENSER:
Quick Steps – Coin Dispenser
To quickly setup the ER-A520/ER-A530 to interface with a coin dispenser, please refer to the
outlined procedures below:
No.
Description
Step–1
Connect the Coin Dispenser
Step–2
PGM Job#2690
Step–3
Program Reset
Step–4
PGM Job#2510
Specifications subject to change without notice: Revision date 10/07
Comments/Procedure
CH–1 or CH–2
2690
[.]
[@]
1
or
2690
[.]
[@]
1
Note:
Must match the physical connection
Place the SRV-Key counter-clockwise to 6 o'clock position
(SRV' position)
Count 5 seconds
Turn SRV-Key clockwise to 7o'clock position (SRV position)
Verify"***PROGRAM RESET has printed on the journal-side
tape.
Verify that the Cashiers have a valid Drawer Assignment (1 or 2)
PERIPHERALS
@
0001 [SBTL]
[CA/AT] for CH–1)
@
0002 [SBTL]
[CA/AT] for CH–2)