TVL2000
Notice:
Be sure to follow figures two and three when making your own
DMX512
cables. Do not use the ground lug on the XLR connector. Do not con-
DMX+,DMX-,COMMON
nect the cable's shield conductor to the ground lug or allow the shield
conductor to come in contact with the XLR's outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX512 OUT
3-PIN XLR
XLR Male Socket
1 Ground
2 Cold
2 Cold
REMOTE
INPUT
OUTPUT
CONTROL
INPUT
3 Hot
Figure 3
Special Note: Line Termination.
POWER
used, you may need to use a terminator on the last unit to avoid erratic
behavior. A terminator is a 90-120 ohm 1/4 watt resistor which is con-
nected between pins 2 and 3 of a male XLR connector (DATA + and
DATA -). This unit is inserted in the female XLR connector of the last
unit in your daisy chain to terminate the line. Using a cable terminator
(ADJ part number Z-DMX/T) will decrease the possibilities of erratic
behavior.
Termination reduces signal errors and
avoids signal transmission problems
1
1
DMX512 IN
and interference. It is always advisable
3
3
3-PIN XLR
to connect a DMX terminal, (Resistance
2
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
©Elation Pr
fessionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 6
o
POWER
COMMON
DMX +
1
1
DMX512 IN
3
3
3-PIN XLR
DMX -
2
2
XLR Female Socket
XLR Pin Configuration
1 Ground
Pin 1 = Ground
REMOTE
INPUT
OUTPUT
SOUND
CONTROL
Pin 2 = Data Compliment (negative)
INPUT
3 Hot
Pin 3 = Data True (positive)
When longer runs of cable are
Figure 4
Set Up
TVL2000
POWER
First unplug the power. Locate and remove the unit's power cord.
Once the cord has been removed located the fuse holder located
inside the power socket. Insert a flat-head screw driver into the power
socket and gently pry out the fuse holder. Remove the bad fuse and
replace with a new one. The fuse holder has a built-in socket for a
spare fuse be sure not to confuse the spare fuse with active fuse.
TVL2000
Termination reduces signal errors and
avoids signal transmission problems
1
and interference. It is always advisable
3

Fixture Cleaning:

to connect a DMX terminal, (Resistance
2
120 Ohm 1/4 W) between PIN 2 (DMX-)
Figure 2
and PIN 3 (DMX +) of the last fixture.
internal and external optical lenses and mirror should be carried out
periodically to optimize light output. Cleaning frequency depends on
the environment in which the fixture operates (I.e. smoke, fog residue,
dust, dew). In heavy club use we recommend cleaning on a monthly
basis. Periodic cleaning will ensure longevity, and crisp output.
1. Use normal glass cleaner and a soft cloth to wipe down the out-
side casing.
2. Use a brush to wipe down the cooling vents and fan grill.
3. Clean the external optics and mirror with glass cleaner and a soft
cloth every 20 days.
4. Clean the internal optics with glass cleaner and a soft cloth every
POWER
30-60 days.
5. Always be sure to dry all parts completely before plugging the unit
back in.
TVL2000
Trouble Shooting: Listed below are a few common problems that
you may encounter, with solutions.
No light output from the unit;
1. Be sure the external fuse has not blown. The fuse is located on
the rear panel of the unit.
2. Be sure the fuse holder is completely and properly seated.
©Elation Pr
POWER
Due to fog residue, smoke, and dust cleaning the
fessionals® - www.elationlighting.com - TVL2000 Instruction Manual Page 15
o
Fuse Replacement
Cleaning
Trouble Shooting

Advertisement

Table of Contents
loading

Table of Contents