Groen TDB/6 Operator's Manual
Groen TDB/6 Operator's Manual

Groen TDB/6 Operator's Manual

Steam jacketed kettle
Hide thumbs Also See for TDB/6:

Advertisement

Quick Links

? IMPORTANT INFORMATION
OPERATOR MANUAL
Part Number 121005
MODEL: TDB/6
Steam Jacketed Kettle
Self-Contained
Electrically heated
Table top mounted
Tilting
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ,
UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS MANUAL.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER
APPLIANCE.
? KEEP FOR OPERATOR
FOR YOUR SAFETY
Information contained in this document is
known to be current and accurate at the time
of printing/creation. Unified Brands recom-
mends referencing our product line websites,
unifiedbrands.net, for the most updated
product information and specifications.
? IMPORTANT INFORMATION
OM-TDB/6
?
DOMESTIC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDB/6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Groen TDB/6

  • Page 1 ? IMPORTANT INFORMATION ? KEEP FOR OPERATOR ? IMPORTANT INFORMATION OM-TDB/6 OPERATOR MANUAL Part Number 121005 DOMESTIC MODEL: TDB/6 Steam Jacketed Kettle Self-Contained Electrically heated Table top mounted Tilting THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL.
  • Page 2: Important Operator Warnings

    OM-TDB/6 IMPORTANT — READ FIRST — IMPORTANT CAUTION: BE SURE ALL OPERATORS READ, UNDERSTAND AND FOLLOW THE OPERATING INSTRUCTIONS, CAUTIONS, AND SAFETY INSTRUCTIONS CONTAINED IN THIS MANUAL. WARNING: THIS UNIT IS INTENDED FOR USE IN THE COMMERCIAL HEATING, COOKING AND HOLDING OF WATER AND FOOD PRODUCTS, PER THE INSTRUCTIONS CONTAINED IN THIS MANUAL.
  • Page 3: Table Of Contents

    THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE OPERATOR INJURY AND DAMAGE TO THE EQUIPMENT, AND WILL VOID ALL WARRANTIES.
  • Page 4: Equipment Description

    OM-TDB/6 Equipment Description The Groen TDB/6 is a table top, tilting, steam A built-in steam generator, sized for the kettle jacketed kettle with a thermostatically controlled, capacity and heated by electricity, delivers self-contained, electrically-heated steam supply steam into the jacket. “Airless” operation of the...
  • Page 5: Installation

    (A BX service panel. Any mechanical or electrical connection is not recommended.) changes must be approved in by Groen’s Food Service Engineering Department. DANGER ELECTRICALLY GROUND THE UNIT...
  • Page 6: Initial Start-Up

    If the unit functions as described above, it is indicator light should come on ready for use. If the unit does not function as immediately, and heating should intended, contact your local Groen Certified continue until the water boils. Service Agency.
  • Page 7: Operation

    OM-TDB/6 Operation WARNING AVOID CONTACT WITH SURFACES. DIRECT SKIN CONTACT COULD RESULT IN SEVERE BURNS. AVOID ALL DIRECT CONTACT WITH HOT FOOD WATER KETTLE. The operator controls kettle heating with the DIRECT CONTACT COULD RESULT IN thermostat dial. The dial turns heating element SEVERE BURNS.
  • Page 8 OM-TDB/6 a) Firmly grasp the plastic handle b) Lift rear edge (farthest from operator) 1- 2” (3-5 cm) to allow any steam and water vapor to escape the cooking vessel. Wait 2-3 seconds. CAUTION KEEP FLOORS FRONT c) Tilt cover to 45-60° angle and allow any KETTLE AREA CLEAN AND DRY.
  • Page 9: Sequence Of Operation

    OM-TDB/6 d) Slowly lower product into kettle. e) When removing basket with cooked product, lift the basket straight up, using both hands and ensuring that the bottom of the basket clears the rim and pouring lip of the kettle. Wear protective oven mitts and a protective apron.
  • Page 10: Cleaning

    OM-TDB/6 Cleaning b. Scrape and flush out food residues. Be 1. Suggested Tools: careful not to scratch the kettle with metal implements. a. Cleaner, such as Klenzade HC-10 or HC-32 from ECOLAB, Inc. c. Prepare a hot solution of the detergent/ cleaning compound as instructed by the b.
  • Page 11 Groen Delimer/Descaler (Part Number 114800) or Lime-Away® from g. The outside of the unit may be polished Ecolab, in accordance with the with a stainless steel cleaner such as manufacturer’s directions.
  • Page 12: Maintenance

    OM-TDB/6 Maintenance NOTICE: Contact Groen or an authorized Groen representative when repairs are required. 1. Periodic Maintenance operating at five PSI by lifting the test lever to release steam. A Maintenance & Service Log is provided at the back of this manual with the warranty information.
  • Page 13 OM-TDB/6 3. Jacket Filling and Water Treatment c. Measure the water treatment compound you will be using. (One way to do this is The jacket was charged at the factory with to add the compound from a measuring the proper amount of treated water. You may cup.)
  • Page 14: Troubleshooting

    OM-TDB/6 Troubleshooting Your Groen kettle will operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. Items marked with an should only be performed by a qualified Groen Service Representative.
  • Page 15: Parts List

    OM-TDB/6 Parts List Description Part No. Description Part No. Kettle Assembly 002978 10 Street Elbow, 1/2" NPT 004185 Basket 001110 11 Grommet 007400 Cover Assembly 001108 12 Nipple Assembly 003440 Knob 001385 13 Bracket 002916 Safety Valve, 50 PSI 096905...
  • Page 16 OM-TDB/6 Parts List (Continued) Description Part No. Description Part No. Knob, Thermostat 002868 31 Clamp 007870 Flange, Bearing 002859 32 Nut, Hex, #10-32 011032 Snap Ring 006792 33 Contactor 009178 Cover, Pedestal, Top 096932 34 Pressure/Vacuum Gauge 084208 Strip, Insulator...
  • Page 17: Diagrams & Schematics

    OM-TDB/6 References KLENZADE SALES CENTER ECOLAB. Inc. 370 Wabasha St. Paul, Minnesota 55102 800/352-5326 or 612/293-2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy, Massachusetts 02269 NFPA/70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Rd. Ann Arbor, Michigan 48106 UNDERWRITERS LABORATORIES, INC.
  • Page 18: Maintenance Log

    OM-TDB/6 Service Log Model No. ________________________ Purchased From ___________________ Serial No. _______________________ Location _________________________ Date Purchased ___________________ Date Installed _____________________ Purchase Order No. ________________ For Service Call ___________________ Date Maintenance Performed Performed by...
  • Page 19: Warranty

    Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for (12) twelve months with the following conditions and subject to the following limitations.
  • Page 20 1055 Mendell Davis Drive OM-TDB/6 (Revised 12/97) Jackson, MS 39272 Telephone (601) 372-3903 Part Number 121004 Fax (601) 373-9587...

Table of Contents