Groen TDB/6 Operators & Service Manual

Groen TDB/6 Operators & Service Manual

Steam jacketed kettle
Hide thumbs Also See for TDB/6:

Advertisement

Quick Links

OPERATOR &
SERVICE MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODEL TDB/6
STEAM JACKETED KETTLE
Domestic
· Self Contained
· Table Top Mounted
· Electrically Heated
· Tilting
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt
of same and to determine the possibility of any damage, including concealed
damage. Unified Brands suggests that if you are suspicious of damage to
make a notation on the delivery receipt. It will be the responsibility of the con-
signee to file a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 148732, REV. G (03/15)
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDB/6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Groen TDB/6

  • Page 1 OPERATOR & SERVICE MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: MODEL TDB/6 STEAM JACKETED KETTLE Domestic · Self Contained · Table Top Mounted · Electrically Heated · Tilting THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
  • Page 2: Important Operator Warnings

    FAILURE TO CHECK PRESSURE RELIEF VALVE OPERATION PERIODICALLY COULD RESULT IN PERSONAL INJURY AND/OR DAMAGE TO EQUIPMENT. WARNING: WHEN TESTING, AVOID ANY EXPOSURE TO THE STEAM BLOWING OUT OF THE PRESSURE RELIEF VALVE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS. OM-TDB/6...
  • Page 3 PROTECTIVE CLOTHING. CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED. CAUTION: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE OPERATOR INJURY AND DAMAGE TO THE EQUIPMENT, AND WILL VOID ALL WARRANTIES.
  • Page 4: Table Of Contents

    Quincy, Massachusetts 02269 NFPA/70 - The National Electrical Code NSF INTERNATIONAL 789 N. Dixboro Road P.O. Box 130140 Ann Arbor, Michigan 48113-0140 UNDERWRITERS LABORATORIES, INC. 333 Pfingsten Road Northbrook, Illinois 60062 ZEP MANUFACTURING CO. 1310-T Seaboard Industrial Blvd. Atlanta, Georgia 30318 OM-TDB/6...
  • Page 5: Equipment Description

    A single electrical connection is required for installation. The unit employs single phase 208 or 240 volt power. KETTLE CHARACTERISTICS Description TDB/6 Kettle Capacity 10 qt / 9.4 liter Jacket Capacity 1 quart / 0.9 liter Inside Diameter 12 in / 30.5 cm...
  • Page 6: Inspection And Unpacking

    Attach the tilt handle (normally shipped inside the kettle) by carefully threading it into the socket on the trunnion support. Be careful to avoid cross-threading the fine threads on the trunnion. NOTE: After handle installation on the right hand side, retain the hardware supplied with the unit for left hand installation. OM-TDB/6...
  • Page 7: Installation

    Installation WARNING The TDB/6 Kettle is provided with complete internal wiring and is ready for immediate INSTALLATION OF THE KETTLE MUST BE connection. A wiring diagram is provided in this manual and on the inside of the DONE BY A CERTIFIED ELECTRICIAN OR control housing service panel.
  • Page 8: Initial Start-Up

    If the unit functions as described above, it is ready for use. If the unit does not function as intended, first recheck power supply connections and, if necessary, contact your local Certified Service Agency. A simple turn of the thermostat controls the kettle. OM-TDB/6...
  • Page 9: Operation

    ALWAYS use the plastic handle to place or remove cover from the kettle. Wear protective oven mitts and a protective apron. When putting the cover on the kettle, position it on top of kettle rim, with its flat edge facing the pouring lip. OM-TDB/6...
  • Page 10 Place baskets with food on a stable, flat surface, inside a solid steamer or bake pan,to catch any remaining hot water draining from product. OM-TDB/6...
  • Page 11: Sequence Of Operation

    In the event that the jacket water level gets too low and the heating elements overheat, the high limit control will open and shut off power to the elements until the kettle cools. Setting the operating thermostat dial to “OFF” shuts down all control and heating circuits. OM-TDB/6...
  • Page 12: Cleaning

    Clean the unit thoroughly, inside and Don’t scrape with tools, steel wool or other outside. abrasives. Rinse the kettle thoroughly with hot Clean the unit thoroughly, inside and water, then drain completely. outside. Rinse the kettle thoroughly with hot water, then drain completely. OM-TDB/6...
  • Page 13 Rinse and drain the unit thoroughly before further use. If especially difficult cleaning problems persist, contact your cleaning product supplier for assistance. The supplier has a trained technical staff with laboratory facilities to serve you. OM-TDB/6...
  • Page 14: Maintenance

    From time to time, you may need to restore the water to its proper level. The procedure for adding water follows. OM-TDB/6...
  • Page 15 Use a measuring cup to add the compound so that you may record the exact amount used. The amount may be used again, if the same water sources and compound are used in the future. However, it is best to check the pH each time treated water is prepared. OM-TDB/6...
  • Page 16: Troubleshooting

    Thermostat operation. Thermostat should click when the dial is rotated above and below the setting for the temperature of the kettle. X d. Pressure relief valve. If the valve pops at pressures below 49 PSI, replace it. e. Contactor, to determine whether it is energized. X OM-TDB/6...
  • Page 17: Parts List

    Parts List 10 d 10 e 10 a OM-TDB/6...
  • Page 18 Parts List 10 f 10 c 10 b 18,19 element OM-TDB/6...
  • Page 19 SCREW, ROUND HEAD, MACHINE, 4-40 X 3/4" LONG 003122 THERMOSTAT, HI-LIMIT 004588 THERMOSTAT, CONTROL 012313 PROBE, WATER LEVEL 096959 COVER, ELEMENT HOUSING 002915 GASKET, COVER 007937 3 FT OVERLAY, FRONT 135735 HARNESS 148534 DIAGRAM, WIRING 148543 BRACKET, FAUCET 131931 OM-TDB/6...
  • Page 20: Wiring Diagram

    Wiring Diagram OM-TDB/6...
  • Page 21: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-TDB/6...

Table of Contents